Initializing of the flash is one way to clear a corrupted configuration file and is required before a
Return Merchandise Authorization (RMA).
Corruption of flash recovery tree
Figure 5: Corruption of flash
Incorrect PVID
An issue can occur where clients cannot communicate to critical servers when their ports are
put in wrong VLAN. If the server is plugged in VLAN-3 and the PVID of the port is 2 then loss of
communication can occur. This can be verified by checking the PVID of the ports.
Emergency recovery trees
22 Troubleshooting
November 2010