Table 10-61.
TEST #621 Level 1 Status Inquiry
Error
Code
Test
Result
Description/Recommendation
1187
ABORT
The board, port, or station may have been busied-out by a
technician.
1. Look in the Error Log for Error Type 18 (port busied out)
for this port and ASAI-BD (board busied out). If this error
type is present for ASAI-PT only, then release the port
using the release port pp command and run the test
again. If the error is present for both ASAI-BD and
ASAI-PT, then release the board with the release port
PCSS command and run the test again.
NOTE:
When you release a port, you release all ports
associated with it. If certain ports still need to be busied
out, use the release port PCSSpp command to busy
them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5
times.
2000
ABORT
Response was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset
the circuit pack using the busyout board PCSS and
reset board PCSS commands.
2. If the test aborts again, replace the circuit pack.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...