AN-LN-PT (Analog Line Port)
Issue 4 May 2002
10-111
555-233-123
AN-LN-PT (Analog Line
Port)
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID), and the TN797
Analog Trunk and Line circuit pack both support this Maintenance Object.
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID) provides 24 ports
for voice terminals and supports both on-premises and off-premises analog voice
terminals.
The TN797 Analog Trunk and Line circuit pack provides 8 ports, each of which
may be administered in any of several ways, as described in maintenance object
TR-LN-BD.
NOTE:
The TN793B/TN2793B analog line circuit pack supports analog data
modules. When assigned, analog data modules provide access to the
NetPkt (TN2401/TN794 circuit pack) data ports. To activate an analog data
module you must assign the port location on the data form and connect a
modem to the port. The analog data module can be used for connection to a
CDR output, or other adjuncts as needed. These ports are tested the same
as all other analog ports on the circuit pack.
Ringing caused by maintenance testing
Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing disturbs the customer or the terminal equipment,
disable it in the
Tests
field of the change station extension form. Be aware that
this action also disables Tests #6, 7, 161, and 35 on some software releases.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to
Run
1
1
UU is the universal cabinet number (1 for PPN, 2 -3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, etc.).
Full Name of MO
AN-LN-PT
MIN
test port UUCSSpp l
Analog Line Port
AN-LN-PT
WRN
test port UUCSSpp sh
Analog Line Port
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...