ANL-16-L (16-Port Neon Analog Line)
Issue 4 May 2002
10-75
555-233-123
Station Status and Translation Audits and
Updates Test (#36)
This test updates the Analog port’s message lamp state (if it has one) and
translations (such as station type, dial type, network connection) with information
kept in the software. The software is updated with the switchhook state reported
by the port processor. When the ringer is in the off state, this test also turns off the
station’s ringer to prevent constant ringing caused by defective hardware.
Table 10-28. TEST #36 Station Status and Translation Audits and Updates Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run
this test.
1. Retry the command at 1-minute intervals a maximum of
5 times.
1004
ABORT
The port was seized by a valid call during the test. The test
has been aborted. Use the display port PCSSpp command
to determine the station extension. Use the status station
command to determine the service state of the port. If the
service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is
idle before retesting.
1. Retry the command at 1-minute intervals a maximum of
5 times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005
ABORT
The test was aborted due to a configuration problem. This
test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the
modem pool member or music on hold).
1006
ABORT
This port has been busied out by command, or taken
out-of-service by the failure of the NPE Crosstalk Test.
1. Look in the error log for error type 18 (port busied out) for
this port. If this error is present, release the port with the
release station extension command, and run the test
again.
2. Look in the error log for error type 1025 (NPE crosstalk
test failed) for this port. If this error is present, investigate
the errors associated with the NPE Crosstalk Test 6.
3. Make sure that the terminal is connected and in service,
and then retest.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...