Conference Circuit Test (#7)
One or more NPEs reside on each circuit pack with a TDM Bus interface. The
NPE controls port connectivity and gain, and provides conferencing functions on a
per-port basis. The Conference Circuit Test verifies that the NPE channel for the
port being tested can correctly perform the conferencing function. The NPE is
instructed to listen to several different tones and conference the tones together.
The resulting signal is then measured by a Tone Detector port. If the level of the
tone is within a certain range, the test passes.
Table 10-26. TEST #7 Conference Circuit Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the station extension. Use
the status station command to determine the service state of
the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test
has been aborted. Use the display port PCSSpp command
to determine the station extension. Use the status station
command to determine the service state of the port. If the
service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is
idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005
ABORT
The test was aborted due to a configuration problem. This
test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the
modem pool member or music on hold).
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...