Packet Bus Fault Isolation and Correction
555-233-123
9-18
Issue 4 May 2002
Special Precaution Concerning the TN771
NOTE:
A new TN771 Maintenance/Test circuit pack must be taken to the customer
site whenever the following is true:
■
Maintenance/Test Packet Bus port indicates that a Packet Bus fault is
present.
NOTE:
Such a fault is indicated by a Major or Minor alarm against the Packet
Bus. A Major alarm is indicated in the error log by Error Type 513,
while a Minor alarm is indicated by Error Type 2049.
■
Test #572 of the PKT-BUS test sequence is the only test that fails.
This precaution is taken because certain failures of the Maintenance/Test circuit
pack can appear as Packet Bus failures. To ensure that the problem is indeed with
the Packet Bus, implement the following steps:
1. Refer to the M/T-PKT Maintenance documentation in
‘‘Maintenance Object Repair Procedures’’
. Correct any problems with the
TN771 Maintenance/Test Packet Bus port as described in that section. If
the TN771 Maintenance/Test circuit pack is replaced during the correction
process, enter the test pkt P long command to determine if the Packet
Bus faults have been resolved. If there are still Packet Bus problems,
correct them by using the procedures in the sections that follow.
2. If the Maintenance/Test circuit pack was not replaced, enter the test pkt P
command. Record the results (PASS/FAIL/ABORT) and error codes for
Test #572.
3. Enter the status system P command. Record the information listed for the
Packet Bus.
4. Busyout the Maintenance/Test circuit pack by entering the busyout board
PCSS command.
5. Replace the Maintenance/Test circuit pack with the new circuit pack.
6. Release the Maintenance/Test circuit pack by entering the release board
PCSS command.
7. Enter the test pkt P and status system P commands as described in
Steps 2 and 3.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...