Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-124
Issue 4 May 2002
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
test environment
Help Messages
If the system technician presses
HELP
after entering “test environment,” the
following message appears:
Enter [cabinet(1-3)],[’long’ or ’short’],
[’repeat’(1-100) or ’clear’],[’schedule’]
Error Messages
If the entered cabinet location is greater than two characters or otherwise invalid,
the following error message appears:
Identifier invalid
If the indicated EPN is not available, the following message appears:
EPN is not available
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
test hardware-group
Help Messages
If the system technician presses
HELP
after entering “test hardware-group” the
following message appears:
board cabinet carrier spe system
If the system technician presses
HELP
after entering “test hardware-group board”
the following message appears:
Enter board location: [cabinet (1-3);
carrier (A-E);slot(00-20)]
If the system technician presses
HELP
after entering “test hardware-group cabinet”
the following message appears:
Enter cabinet (1-3)
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...