
test duplication-interface
Issue 4 May 2002
A-123
555-233-123
test duplication-interface
Help Messages
If the system technician presses
HELP
after entering “test duplication-interface,”
the following message appears:
Enter [network(1);carrier(A-B) [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
For any system, if a user entered parameter is not among those listed in the
“Parameters” section, the following message appears:
Entry invalid
If an invalid port network is specified, the following message appears:
Invalid port-network specified
If an invalid carrier is specified, the following message appears:
Invalid carrier specified
If the standby is entering maintenance mode when this command is executed,
then the following message appears:
Cannot interrupt Standby SPE while entering
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the
following message appears:
Standby SPE memory not refreshed;
use the “refresh spe-standby” command.
If the standby SPE is not refreshed and the active SPE is hard selected via the
SPE select switches when this command is executed, then the following message
appears:
Active SPE locked via select switches;
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message appears:
Standby SPE busy with another task;
for information use “status system 1"
If the standby SPE is not available when this command is executed, then the
following message appears:
Standby SPE not available;
for information use “status system 1"
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...