status isdn-testcall
Issue 4 May 2002
A-101
555-233-123
status isdn-testcall
Help Messages
If the system technician presses
HELP
after entering “status isdn-testcall”, the
following appears:
Enter group #/member # [’print’]
Error Messages
If the specified format of the trunk location is incorrect, the following message
appears:
Format invalid
If the specified trunk group or member range is invalid, the following message
appears:
Trunk or trunk group invalid
If a trunk group and member is not specified, the following message appears:
Must specify group/member pair
\If the specified trunk group is not administered or has no members administered,
the following message appears:
Group not assigned,
or group assigned but with no member
If the specified trunk group member is not administered, the following message
appears:
Group member not assigned
If a test call is currently not in progress when the command is entered, the
following message appears:
Test Call not in progress
If the specified trunk is not an ISDN-PRI trunk, the following message appears:
Invalid non ISDN-PRI trunk specified
If software data cannot be sent to the SAT, the following message appears:
Error encountered, can’t complete request
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...