UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1915
555-233-123
The CPE Loopback Jack Test has the UDS1 Interface circuit pack transmit a
loopback activation code to the CPE Loopback Jack, waits up to 10 seconds for
return of the code to verify the loopback has been established, transmits a framed
3-in-24 test pattern, begins counting bit errors in the received test pattern, and
returns a PASS result to indicate that the pattern was successfully sent. If the
loopback is not established within the 10 seconds, the test returns FAIL or abort.
The status of the CPE Loopback Jack test is available in the hardware error log
via Error Type 3900. Several distinct Aux values give the user information on the
status of the test.
The list measurements ds1 summary command will display the length of time
the test has been running (
Test Duration
field) and number of bit errors
detected (
Loopback/Span Test Bit-Error Count
field). If the test pattern is
being passed through the loopback cleanly, the number of bit errors should be
very low. The command will also display the type of Loopback/Span test executing
(
Test
field), the type of pattern generated for the Loopback/Span test (
Pattern
field), and whether the pattern (i.e. 3-in-24 Pattern) is synchronized
(
Synchronized
field).
To terminate the test, use test ds1-loop UUCSS end-loopback/span-test or
release board. Using release board restores all trunks or ports on the UDS1
Interface circuit pack to the in-service state.
Table 10-685.
TEST #1212 CPE Loopback Jack Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the test ds1-loop UUCSS
cpe-loopback-jack-test-begin command at 1-minute
intervals a maximum of 5 times.
1005
ABORT
CPE Loopback Jack Test cannot be executed in the current
configuration. To run this test, the TN464F or later suffix UDS1
must be administered for 24-channel operation. The “Bit Rate”
field on the DS1 circuit pack administration form must be set to
“1.544” for 24-channel operation.
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied
out to out-of-service.
1. Enter the busyout board UUCSS command to put all
trunks or ports of the UDS1 Interface circuit pack into the
out-of-service state.
2. Retry the command.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...