
Maintenance Object Repair Procedures
555-233-123
10-1846
Issue 4 May 2002
Notes:
a. Error Type 1 — indicates that the circuit pack has totally stopped
functioning or is not fully administered. The alarm is logged about 15
minutes after the circuit pack has been removed or 11-minutes after the
SAKI Test (#53) fails.
To be fully administered, a UDS1 circuit pack must meet all three of the
following conditions:
1. Have an entry in the circuit plan using the change circuit pack
command
2. Be administered using the add ds1 UUCSS command
3. Be physically inserted into the correct slot
If the circuit pack has an entry in the circuit plan and either of the other two
conditions are not met, a MINOR alarm is logged. To resolve the error
either:
1. Make sure that all conditions for administration are met and that a
functioning UDS1 circuit pack is inserted in the correct slot, or
3843(ab)
46081
3900(ac)
Any
CPE Loopback Jack
Test (#1212)
3901(ad)
Any
Far CSU Loopback
Test (#1213)
3902(ae)
Any
One-Way Span Test
(#1214)
3999(af)
Any
None
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the
circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been missing
for a period of 15 minutes. Warning alarms are also raised against any ports administered on the
circuit pack.
3
Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
4
Major alarms on this MO may be downgraded to minor or warning alarms based on values set in the
set options command.
Table 10-667.
DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm Level
On/
Off
Board
Test to Clear Value
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...