busyout pms-link
Issue 4 May 2002
8-13
555-233-123
Output
The following example shows the output from the busyout packet-control 1A
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field descriptions
busyout pms-link
This command places all maintenance objects associated with a property
management system link in the maintenance busy state. No periodic or scheduled
maintenance is performed on the busied out maintenance objects until they are
released. When the object is maintenance busy the object is deactivated (no call
processing activity may include the busied object) and the link is dropped.
Warning alarms (error type 18) are generated on each busied out maintenance
object, so that INADS can determine the state of the objects. The release pms
link command reactivates the busied out objects on the link.
These links provide asynchronous data connections from switches to peripherals;
they are composed of a:
■
Far-end data module
■
Simulated data channel on a NETCON board
■
Manager that initiates and maintains the link
■
Controller/protocol that services the link
Port
Port address (cabinet-carrier)
Maintenance Name
Type of busied out maintenance object (PKT-CTRL).
Alt. Name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of codes by test number for each MO.
busyout packet-control 1A SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
1A PKT-CTRL PASS
Command successfully completed
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...