busyout data-module
This command puts the specified data module in a maintenance busy state, even
uninstalled data modules. No periodic or scheduled tests is performed on the
busied out data module or data channel until it is released and no call processing
can be executed on the data modules or over the data channels. Warning alarms
are generated (error type 18) on each maintenance object busied out, so that
INADS can access the state of the objects. The release data module command
returns the specified data module (or data channel) to operation.
On duplicated systems, a busyout of a Network Control Data Channel
(DATA-CHL) or a Processor Interface Port Data Channels (PI-PT) are preserved
across SPE interchanges. The data channel extension must be released before
the data channel can be brought back into service.
Output
The following example shows the output from busyout data-module 300.
Action/Object
Qualifier
Qualifier
Description
Logins
Defaults
Feature
Interactions
busyout
data-module
extension
Extension number
(per dial-plan)
Example:
busyout
data-module 31300
init
inads
craft
nms
None
None
busyout data-module 300 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1103 DIG-LINE 300 PASS
Command successfully completed
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...