Maintenance Object Repair Procedures
555-233-123
10-1680
Issue 4 May 2002
Table 10-618.
TEST #1242 Level 1 Status Inquiry
Error
Code
Test
Result
Description/Recommendation
1187
ABORT
The board or port may be busied out.
1. Look in the Error Log for Error Type 18 (port busied out)
for this port and TBRI-BD (board busied out). If this error
type is present for TBRI-PT only, then release the port
with the release port PCSSpp command and run the
test again. If the error is present for both TBRI-BD and
TBRI-PT, then release the board with the release board
PCSS command and run the test again.
NOTE:
When you release a port, you release all ports
associated with it. If certain ports still need to be busied
out, use the release port PCSSpp command to busy
them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5
times.
2000
ABORT
Response to the test was not received from the circuit pack
within the allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset
the circuit pack with the busyout board PCSS and reset
board PCSS commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...