REM-OFF (Remote Office)
Issue 4 May 2002
10-1457
555-233-123
REM-OFF (Remote Office)
An instance of this maintenance object (REM-OFF) is associated with every
Remote Office box that is administered on the switch. This maintenance object
monitors keep alive and periodic PING test failures, and if these errors occur, they
are logged against this maintenance object.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type - 1 — indicates that a PING Test to the Remote Office has
failed, and a MINOR alarm has been raised.
The PING test verifies that a path to a registered Remote Office is good.
When this error is logged, as many as 26 endpoints (associated with that
Remote Office) and several H.323 signaling groups could be out of service.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1
UU is the universal cabinet number (1 for PPN, 2 or 3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
Full Name of MO
REM-OFF
MIN
ping node-name/ip-address
Remote Office
REM-OFF
WRN
ping node-name/ip-address
Remote Office
Table 10-553.
Analog Line Error Log Entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
1(a)
A ping test to
an endpoint
has failed
MINOR
OFF
ping
node-name/ip-address
257(b)
See note
(b)
A keep alive
update
request has
exceeded the
time limit for
an endpoint
Log only
OFF
ping
node-name/ip-address
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...