ID Request Test
—
A request is made to the station for its status. The
station sends its configuration information and health information back.
This information is checked and a pass/fail result is provided.
■
Ringer Update
—
This updates the digital telephone ringer state according
to the processor records.
■
DTMF Administration Update
—
This is a message to the digital station to
refresh the default value that causes the station to send touch- tones only
in the primary information channel. This value is set initially when the
station is put in-service and every time the station’s state changes from
other states to in-service.
Table 10-552.
TEST #17 Station (Digital) Audits Test
Error
Code
Test
Result
Description/Recommendation
1
ABORT
Switchhook audit timed out.
1. Make sure voice terminal is connected and repeat
test.
2. If test fails, replace voice terminal and repeat test.
2
ABORT
ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected and repeat
test.
2. If test fails, replace voice terminal and repeat test.
3
ABORT
The EPF has detected an overcurrent condition.
1. Use test UUCSSpp long. If Test #11 passes, then the
EPF condition was cleared. Rerun the Short Test
Sequence. If Test #11 does not pass, follow the repair
procedures described for Test #11.
2. Look for Error Type 769 logged against RDIG-STA
and follow the procedures in the associated footnote.
If any additional problems are found, rerun the test.
4
ABORT
Internal system error
1. Resolve any outstanding circuit pack maintenance
problems.
2. Retry the command at 1-minute intervals a maximum
of 5 times.
5
ABORT
Ringer update aborted due to station being in ready-for-service
or out-of-service state.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...