Maintenance Object Repair Procedures
555-233-123
10-1366
Issue 4 May 2002
PR-MAINT (Maintenance Processor
[TN2404/TN790 RISC Systems])
The TN2404/TN790 Processor circuit pack is comprised of the RISC Processor
(PROCR), the Maintenance Processor (PR-MAINT), and the Memory (PR-MEM).
PR-MAINT is responsible for monitoring the sanity of the RISC Processor.
PR-MAINT contains the hardware required for controlling the environmental
conditions. The Maintenance/Tape Processor provides the serial interfaces for the
administration terminal and DCE port. The Maintenance Processor also provides
the communications interface to INADS for alarm reporting and remote
maintenance capability. INADS connectivity is through the internal or external
modem. The external modem is connected to the DCE port. When the external
modem is the administered modem option the internal modem is disabled.
The TN2404/TN790 has a higher speed 9600 baud internal modem or can
support an external modem connected to the DCE port.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
PR-MAINT
MIN
1
1
Alarms on the PROCR and PR-MAINT maintenance objects are indicated by the red
LED on the Processor circuit pack.
test processor a/b sh/l
Maintenance Processor
Table 10-505.
PR-MAINT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
1
0
2
0
Any
Any
Any
test processor a/b sh r 1
1(a)
Any
MTP Reset Test (#101)
MIN
ON
test processor a/b l r 3
257(b)
Any
MTP Sanity Handshake
Test (#106)
test processor a/b r 2
513(c)
Any
MTP Analog Loop Around
Test (#103)
MIN
ON
test processor a/b r 8
769(d)
Any
MTP Dual Port Ram Test
(#104)
MIN
ON
test processor a/b l r 3
1025(e)
Any
MTP Outpulse Relay Test
(#102)
MIN
OFF
test processor a/b r 5
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...