Unusual ATM trouble conditions
Issue 4 May 2002
5-99
555-233-123
Action
1. Correct the ATM addresses (or swap fibers) on the A500 between the
incorrectly connected EPNs.
Swapped Routes, End System Identifiers, or Fiber
between A and B side TN230Xs on an EPN
Symptoms
■
The PPN establishes links to what it thinks is the active TN230X on the
EPN.
■
As normal, it reboots this TN230X, and when complete, it resets the EPN.
When this happens, the active (instead of the standby) TN230X reboots,
dropping the links.
■
To recover, the PPN re-establishes links to what it thinks is the active
TN230X and the cycle repeats indefinitely.
Diagnostics
1. The status pnc command on the DEFINITY SAT shows both the A-side
and B-side
State of Health
field as
partially functional
.
Action
1. Correct the ATM addresses (or swap fibers) on the A500 between the A
and B side of the EPN.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...