Routine Maintenance Procedures
555-233-123
5-82
Issue 4 May 2002
Screen 5-20.
A500 screen output for show sys interfaces command
■
For each administered port used by a DEFINITY port network, the
Admin Status
should be
up
(use admin up).
■
Oper Status
is not pertinent to administration of the A500 and is
discussed in a later section.
■
State
should be
present
, indicating that A500 port board
insertion was successful. If
State
is
invalid
, then the A500
believes that the corresponding port board slot is empty or the port
board is not recognized.
It may be necessary to re-administer the A500 port boards. Refer to
the Cajun A500 Quick Reference for further information.
■
If
Admin Status
or
State
is incorrect, the links will not come up
between the PPN and the EPN.
Device Oper Admin State Type
Status Status
_________________________________________________________________
A1.1 up up present STS_3c (MultiMode)
A1.2 up up present STS_3c (MultiMode)
A1.3 down down present STS_3c (MultiMode)
A1.4 down down present STS_3c (MultiMode)
A1.5 down down present STS_3c (MultiMode)
A1.6 down down present STS_3c (MultiMode)
A1.7 down down present STS_3c (MultiMode)
A1.8 down down present STS_3c (MultiMode)
A2.1 down down present STS_3c (MultiMode)
A2.2 down down present STS_3c (MultiMode)
A2.3 down down present STS_3c (MultiMode)
A2.4 down down present STS_3c (MultiMode)
A2.5 down down present STS_3c (MultiMode)
A2.6 down down present STS_3c (MultiMode)
A2.7 down down present STS_3c (MultiMode)
A2.8 down down present STS_3c (MultiMode)
A3.1 down down invalid STS_3c (MultiMode)
A3.2 down down invalid STS_3c (MultiMode)
A3.3 down down invalid STS_3c (MultiMode)
A3.4 down down invalid STS_3c (MultiMode)
A3.5 down down invalid STS_3c (MultiMode)
A3.6 down down invalid STS_3c (MultiMode)
A3.7 down down invalid STS_3c (MultiMode)
A3.8 down down invalid STS_3c (MultiMode)
A4.1 down down invalid STS_3c (MultiMode)
A4.2 down down invalid STS_3c (MultiMode)
A4.3 down down invalid STS_3c (MultiMode)
A4.4 down down invalid STS_3c (MultiMode)
A4.5 down down invalid STS_3c (MultiMode)
A4.6 down down invalid STS_3c (MultiMode)
A4.7 down down invalid STS_3c (MultiMode)
A4.8 down down invalid STS_3c (MultiMode)
Self up up present PROPVIRTUAL
Self up up present SAR
E1.1 up up present TenBaseT
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...