Maintenance Object Repair Procedures
555-233-123
10-918
Issue 4 May 2002
Demand Reset Test (#704)
This test is destructive.
This test executes a comprehensive set of diagnostic tests. The test aborts if the
I/O Processor is in the in-service state. The test takes the I/O Processor
out-of-service if background maintenance has reset it 3 times by within the last 15
minutes.
Table 10-333.
TEST #703 Demand Reset Test
Error
Code
Test
Result
Description/Recommendation
1362
ABORT
I/O Processor is in-service.
1. Determine status of the I/O Processor (display alarms).
2. If the I/O Processor status is OUT, retry the command.
2000
ABORT
Response to the test was not received within the allowable time
period.
1. Retry the command at 1-minute intervals, up to 3 times.
Any
FAIL
Test failed.
1. Retry the command.
2. If the problem persists, replace the TN2401/TN794 NetPkt
circuit pack.
PASS
The I/O Processor diagnostic tests passed.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...