Install DS1 CPE Loopback Jack (T1 Only)
Issue 4 May 2002
5-61
555-233-123
9. Repeat Steps 5 through 8 as desired to observe bit error rate
characteristics. Also, wait 1 to 10 minutes between Steps 5 through 7. One
minute without errors translates to better than a 1 in 10 to the eighth error
rate. Ten minutes without errors translates to better than a 1 in 10 to the
ninth error rate.
10. If the test runs for 1 minute with an error count of 0, confirm that the 3-in-24
pattern error detector is operating properly by entering test ds1-loop
<location> inject-single-bit-error. This causes the 3-in-24 pattern
generator on the DS1 circuit pack to inject a single-bit error into the
transmit pattern. A subsequent list meas ds1 summary <location>
command displays the bit error count. If a count greater than 1 is displayed,
replace the ICSU and retest. If the problem continues, replace the DS1
circuit pack.
Table 5-7.
DS1 Span Troubleshooting
Displayed
Field
Function
Indication
Test: cpe-
loopback-jack
Pattern
3-in-24
The loopback jack test is active.
Synchronized
Y or N
If “y” displays, the DS1 circuit pack has synchronized
to the looped 3-in-24 pattern and is accumulating a
count of the bit errors detected in the pattern until the
test has ended. If “n” displays, retry the test 5 times by
ending the test per Step 11 and re-starting the test per
Step 4. If the circuit pack never synchronizes,
substantial bit errors in the 3-in-24 pattern are likely.
This could be intermittent connections or a broken
wire in a receive or transmit pair in the CPE wiring.
Bit Error
Count
Cumulative
count of
detected
errors
If there are no wiring problems, the counter remains
at 0.
A count that pegs at 65535 or continues to increment
by several hundred to several thousand on each list
meas
command execution indicates intermittent or
corroded connections, severe crosstalk, or
impedance imbalances between the two conductors
of the receive pair or the transmit pair. Wiring may
need replacement.
Note that “ESF error events” counter and the ESF
performance counter summaries (“errored seconds”,
“bursty errored seconds”, and so forth) will also
increment. These counters are not used with the
loopback jack tests. However, they will increment if
errors are occurring. Counters should be cleared
following the test.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...