Maintenance Object Repair Procedures
555-233-123
10-748
Issue 4 May 2002
Table 10-282.
TEST #1282 Link Integrity Inquiry Test
Error
Code
Test
Result
Description/Recommendation
1124
ABORT
Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port
UUCSSpp, status link n, or display data-module).
2. If the link is not enabled, enable the link (change
data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125
ABORT
Ethernet link not in service.
1. Verify whether Ethernet link is in service (status port
UUCSSpp or status link n).
2. If the Ethernet link is not in service, release the link (release
link n or release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
1959
ABORT
Downlink message error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2100
ABORT
Could not locate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...