ETH-PT (Control LAN Ethernet)
Issue 4 May 2002
10-745
555-233-123
TCP/IP PING Test (#1281)
This non-destructive test fails if all the endpoints fail to respond. Use this test to
check the circuitry in the data path for a peer-to-peer IP layer connection.
Table 10-281.
TEST #1281 TCP/IP PING Test
Error
Code
Test
Result
Description/Recommendation
1, 2,
11
ABORT
Internal error
1. Retry the command at 1-minute intervals a maximum of 3
times.
2. If the problem persists, escalate the problem.
7
ABORT
Destination unreachable.
1. Verify that there is a destination to ping in the routing table
(list ip-route and look for destinations reachable through this
ethernet port).
2. If there are no reachable destinations from this port (i.e., no
routes administered on ethernet), administer a route and
retry.
3. Escalate if the problem persists.
1005
ABORT
Incorrect test configuration.
1. Verify Ethernet link is in service (status port UUCSSpp or
status link n).
2. Verify that Ethernet link is enabled (status port UUCSSpp
or status link n or display data-module).
3. Verify routing table has reachable destinations.
4. Repeat the test.
5. If problem persists while the Ethernet link is in service and
enabled, escalate the problem.
1124
ABORT
Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port
UUCSSpp, status link n, or display data-module).
2. If the link is not enabled, enable the link (change
data-module).
3. Repeat the test.
4. Escalate if the problem persists.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...