Maintenance Object Repair Procedures
555-233-123
10-596
Issue 4 May 2002
DIOD-TRK (DIOD Trunk), DIOD-BD
(DIOD Circuit Pack) [G1.2SE]
DIOD-TRK (DIOD Trunk) [G1.2SE]
Direct Inward and Outward Dial (TN429 DIOD) trunks are 2-wire analog lines to
the CO which support the following services:
■
both incoming and outgoing CO calls
■
DID trunk
■
DID Trunk and 1-way Outgoing DIOD
The DIOD Trunk circuit pack provides eight ports for loop-start CO. The circuit
pack is an interface between the 2-wire analog line from the CO and the system’s
(4-wire) TDM Bus.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
1
1
Where P is the port network number (1 for PPN, 2 for EPN, and 3 for the second EPN);
C is the carrier designation (for example, A, B, C, D, or E); and SS is the address of
the slot in the carrier where the circuit pack is located (for example, 01, 02, etc.)
Full Name of MO
DIOD-BD
2
2
Where 1 is Long, s is Short, and r is repeat. Refer to the XXX-BD (Common Port
Board) Maintenance Documentation.
MINOR
test port PCSS s
DIOD Circuit Pack
MO Name
(in Alarm Log)
Alarm Level
Initial Command to Run
1
1
Where P is the port network number (1 for PPN, 2 for EPN, and 3 for the second EPN);
C is the carrier designation (for example, A, B, C, D, or E); and SS is the address of the
slot in the carrier where the circuit pack is located (for example, 01, 02, etc).
Full Name of MO
DIOD-TRK
MAJOR
2
2
A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by
the set options command and that at least 75 percent of the trunks in this trunk group
are alarmed.
test port PCSSpp l
DIOD Trunk
DIOD-TRK
MINOR
test port PCSSpp l
DIOD Trunk
DIOD-TRK
WARNING
test port PCSSpp l
DIOD Trunk
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...