
Maintenance Object Repair Procedures
555-233-123
10-582
Issue 4 May 2002
■
EPF/PTC Inquiry Test
—
For a TN413 or a TN754 vintage 13 or earlier, the
status of the Electronic Power Feed (EPF) is sent uplink. Possible
conditions are: EPF-on-ok, EPF-off, and EPF-no-load. For TN754 vintage
14 or later, TN754B or TN2136, TN2181, TN2224, the status of the Positive
Temperature Coefficient (PTC) is sent uplink. Possible conditions are:
PTC-on-ok, PTC-off, and PTC-no-load.
■
ID Request Test
—
A request is made to the station for its status. The
station sends its configuration information and health information back.
This information is checked and a pass/fail result is provided.
■
Ringer Update Test
—
This updates the digital telephone ringer state
according to the processor records.
■
DTMF Administration Update Test
—
This is a message to the digital
station to refresh the default value which causes the station to send
touch-tones only in the primary information channel. This value is set
initially when the station is put in-service and every time the station’s state
changes from other states to in-service.
Table 10-216.
TEST #17 Station (Digital) Audits Test
Error
Code
Test
Result
Description/Recommendation
1
ABORT
Switchhook audit timed out.
2
ABORT
ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
3
ABORT
The EPF/PTC has detected an overcurrent condition.
1. For a TN754 vintage 13 or earlier Digital Line circuit pack,
issue the test PCSSpp long command. If Test #11
passes, then the EPF/PTC condition has been cleared.
Rerun the Short Test Sequence. If Test #11 does not pass,
follow the repair procedures described for Test #11.
2. Look for Error Type 769 logged against DIG-LINE and
follow the procedures in the associated footnote. If any
additional problems are found after completion of
maintenance procedures, rerun the test.
4
ABORT
Internal System Error
1. Resolve any outstanding circuit pack maintenance
problems.
2. Retry the command at 1-minute intervals a maximum of 5
times.
5
ABORT
Ringer update aborted due to station being in ready-for-service
or out-of-service state.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...