Maintenance Object Repair Procedures
555-233-123
10-414
Issue 4 May 2002
Table 10-155.
TEST #42 Tone Detection Verification Test
Error
Code
Test
Result
Description/Recommendation
none
ABORT
The system was not able to allocate all the resources needed
for this test OR there was an Internal System Error.
1
ABORT
The system could not allocate all the resources needed to test
the tones.
1001
ABORT
The system was unable to put the Call Classifier port in the
appropriate mode to test it.
1002
ABORT
The system could not allocate time slots for the test
connection. This situation could occur when the system is
heavily loaded. If the system is not heavily loaded, then test
the TDM-BUS via the test tdm [1|2] command. Refer to the
TDM-BUS (TDM Bus) Maintenance documentation for details.
1. Retry the command at one minute intervals a maximum of
5 times.
1003
ABORT
The system could not allocate a Tone-Clock circuit pack for
the test connection. This situation could occur when the
system is heavily loaded or if a Tone-Clock circuit pack is not
present in the port network when this test is executed.
1. Verify the existence of a Tone-Clock circuit pack in the
same port network.
2. If a Tone-Clock circuit pack is missing, install one in the
same port network.
3. Allow approximately one minute for the Tone-Clock circuit
pack maintenance to run on the newly inserted
Tone-Clock circuit pack.
4. Retry the command at one minute intervals a maximum of
5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...