Maintenance Object Repair Procedures
555-233-123
10-408
Issue 4 May 2002
Table 10-152.
TEST #600 Congestion Query Test
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable
time period.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board
UUCSS).
3. If the problem persists, replace the circuit pack.
2012
ABORT
Could not allocate the necessary system resources to run test.
2100
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1
2
FAIL
FAIL
The buffer level is nearly exhausted.
The CLAN is congested, and no buffers are available.
1. Retry command at 1-minute intervals, up to 5 times.
2. If command continues to fail, examine the CLAN port
measurements to determine which ports are heavily utilized
and the processor occupancy of the circuit pack.
Low processor occupancy when CLAN congested indicates
circuit pack failure.
1. If the problem persists, reset the circuit pack (reset board
UUCSS).
2. If congestion recurs, replace the circuit pack.
High processor occupancy indicates the CLAN is congested due
to traffic load.
1. To relieve congestion in the short term, selectively busyout
ports (busyout port UUcSSpp) on the Control LAN circuit
pack.
2. To achieve a more permanent resolution, it may be
necessary to move ports on this circuit pack to other Control
LAN circuit packs.
3. Consider replacing affected CLAN ports with new ports.
3
FAIL
The CLAN circuit pack is not operating normally and is
congested.
PASS
Hardware setting and attached cable type match CLAN circuit
pack administration. The circuit pack detects no errors.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...