CARD-MEM (Memory Card)
Issue 4 May 2002
10-343
555-233-123
Some other command actions can also interfere with daily maintenance when
certain qualifiers are used in the command, or under certain circumstances. For
example, certain “test” commands, when used with the modifier “continuously”,
could potentially interfere with daily maintenance. However, such command
actions are not used typically by customer administrators doing routine
administration, and are less likely to disrupt daily maintenance routines than are
the add, change, duplicate, remove, and set command actions.
Incomplete Command Time-out
A time-out feature has been added to the MAINTENANCE-RELATED SYSTEM
PARAMETERS form (accessed by the command change system parameters
maintenance). This feature improves the operation of daily maintenance by
allowing maintenance routines to run that might otherwise not run. It also helps to
prevent the loss of translations that were not saved by the save translation
command, and were also not saved because daily maintenance was prevented
from running prior to the system reset. Highlights of the feature include:
■
Options for blank, 1, 2, 3, 4, 5, or 6 hours (the default is 2 hours)
■
The blank option indicates that the feature is not active
■
Only commands that block the running of daily maintenance (add, change,
duplicate, remove, and set) are affected
■
All logins will time-out if any of these commands are active for the
prescribed time (except for the “blank” option)
■
The feature applies to all logins, regardless of type (init, dadmin, craft,
inads) or permissions granted to the specific login ID of an administration
or maintenance user
■
The corresponding “time-out” entry is appended to the list history log
list
save
mark
status
monitor
test
netstat
upgrade
Table 10-132.
DEFINITY Command Actions — Continued
Likely to Disrupt
Less Likely to Disrupt
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...