BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Issue 4 May 2002
10-289
555-233-123
Table 10-115.
TEST #624 Layer 1 Transmission Error Counter Test
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Response to the test was not received from the circuit pack
within the allowable time period.
1. If the test aborts repeatedly a maximum of five times,
reset the circuit pack via the busyout board PCSS and
reset board PCSS commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal System Error.
2100
ABORT
Could not allocate necessary system resources to run test.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
value
FAIL
The BRI-LINE circuit pack is still detecting errors of this
type. The Error Code field contains the value of this
counter.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to fail, review the results of other
tests in the Long Test Sequence. Pay particular
attention to the results of the Level 1 Status Inquiry
test. Follow repair procedures for any of the executed
tests if they fail. Otherwise, go to the next step.
3. If the tests for the endpoints or adjunct pass and the
Layer 1 Transmission Error Counter Test continues to
fail, check the wiring to the endpoints or adjunct. If the
wiring appears to be fine, escalate the problem.
PASS
The Layer 1 Transmission error counter was read correctly
and has a value of 0.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...