AXA12-BD/ADX8D-BD/AXD12-BD (AUDIX Circuit
Packs)
Issue 4 May 2002
10-257
555-233-123
AXA12-BD/ADX8D-BD/AXD12-BD
(AUDIX Circuit Packs)
The TN 568 is a EMBEDDED AUDIX circuit pack that occupies 2 slots on a port
carrier. The tests below apply only to switch-side maintenance, which tests circuit
pack components related to the TDM bus interface. The AUDIX system has an
extensive maintenance strategy of its own that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
AXA12-BD:
On G3r V7 systems, TN568 EMBEDDED AUDIX circuit packs (sometimes called
Embedded AUDIX) operating in control-link mode appear to the system as TN746
Analog Line circuit packs with vintage greater than 50. For circuit-pack-level
problems, see XXX-BD. The maintenance strategy for ports on the TN568
operating in control-link mode is described in ADXCL-PT.
ADX8D-BD:
On G3r V7 systems, TN568 EMBEDDED AUDIX circuit packs operating in 8-port
digital mode appear to the system as TN754 Digital Line circuit packs with vintage
greater than 50. For circuit-pack-level problems, see XXX-BD. The maintenance
strategy for ports on the TN568 operating in 8-port digital mode is described in
ADXDP-PT.
ADX12-BD:
The ADX12-BD maintenance object represents a TN568 EMBEDDED AUDIX
circuit pack operating in 12-port digital (DP) mode. On G3r V7 systems, TN568
EMBEDDED AUDIX circuit packs operating in 12-port digital mode appear to the
system as TN2181 Digital Line circuit packs with vintage greater than 50. For
circuit-pack-level problems, see XXX-BD. Port-level problems are covered by
ADX12D-PT.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
Full Name of MO
AXA12-BD
MINOR
test board UUCSS
1
sh
1
UU is the universal cabinet number (1 for PPN; 2-22 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides)(01 to 21).
AUDIX Circuit Pack
AXA12-BD
WARNING
test board UUCSS sh
AUDIX Circuit Pack
ADX8D-BD
MINOR
test board UUCSS sh
AUDIX Circuit Pack
ADX8D-BD
WARNING
test board UUCSS sh
AUDIX Circuit Pack
AXD12-BD
MINOR
test board UUCSS sh
AUDIX Circuit Pack
AXD12-BD
WARNING
test board UUCSS sh
AUDIX Circuit Pack
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...