Administer Fiber Links
Issue 7 November 2003
A-11
555-233-115
■
DS1CONV Board Location
—
Enter the cabinet, carrier, and slot that
identifies the physical location of DS1 Converter circuit pack in the first
endpoint of the duplicate fiber link. Endpoint-1’s duplicate along with
Endpoint-2’s duplicate make up the duplicate fiber link called the B-PNC
link.
■
DS1CONV Board Type
—
Display-only field showing the type of DS1
Converter circuit pack in Endpoint-1. The circuit pack type in Endpoint-1
(A-PNC) and Endpoint-1 (B-PNC) must be the same. This field is updated
via the Change Circuit-packs command.
■
Board Location
—
Enter the cabinet, carrier, and slot that identifies the
physical location of a circuit pack in the second endpoint of the duplicate
fiber link. Endpoint-2’s duplicate along with Endpoint-1’s duplicate make up
the duplicate fiber link called the B-PNC link.
■
Board Type
—
Display-only field showing the type of circuit pack in
Endpoint-2. The circuit pack type in Endpoint-2 (A-PNC) and Endpoint-2
(B-PNC) must be the same.
■
DS1CONV Board Location
—
Enter the cabinet, carrier, and slot that
identifies the physical location of DS1 Converter circuit pack in the second
endpoint of the duplicate fiber link. Endpoint-2’s duplicate along with
Endpoint-1’s duplicate make up the duplicate fiber link called the B-PNC
link.
■
DS1CONV Board Type
—
Display-only field showing the type of DS1
Converter circuit pack in Endpoint-2. The circuit pack type in Endpoint-2
(A-PNC) and Endpoint-2 (B-PNC) must be the same. This field is updated
via the Change Circuit-packs command.
DS1C Converter Complex Administration for TN574 Circuit Packs.
Screen A-3.
Fiber Link Administration form for TN574 Circuit Pack (DS1 Converter
Complex Administration) (page 2 of 3)
add fiber-link next
Page 2 of 3
FIBER LINK ADMINISTRATION
A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
DS1CONV Board Location: 01B01
DS1CONV Board Location: 02B01
DS1CONV Board Type: TN574
DS1CONV Board Type: TN574
DS1 CONVERTER FACILITIES
A
B
C
D
Facility Installed?
yes
no
no
no
Passes Far-end Clock?
yes
yes
yes
yes
Digital Data Compatible?
yes
yes
yes
yes
Line Coding:
ami-zcs ami-zcs
ami-zcs
ami-zcs
Framing Mode:
esf
esf
esf
esf
DS1CONV-1 Line Compensation:
1
1
1
1
DS1CONV-2 Line Compensation:
1
1
1
1
Facility A Circuit ID: 09876543