DEFINITY AUDIX Power Procedures
Issue 7 November 2003
3-25
555-233-115
Back Up Disk
1. Type backup disk and press
Enter
to back up all changed files to the
removable media. This takes about 15 minutes.
2. Type test stored-data and press
Enter
to verify the consistency of the MSS
files on the disk and removable media.
3. Type list configuration software-version and press
Enter
to verify all the
files one last time.
Set Core Dump Vector
1. Type set vector f spe-maint and press
Enter
to set the core dump vector to
perform a core dump on any system restart.
Return Replaced Equipment
1. Return replaced equipment to Avaya according to the requirements
outlined in:
BCS/Material Logistics, MSL/Attended Stocking Locations
Methods and Procedures for Basic Material Returns
DEFINITY AUDIX Power Procedures
Power Down the AUDIX System
A yellow caution sticker on the system’s power unit notifies technicians to shut
down the DEFINITY AUDIX System prior to powering down the system.
1. Log into the AUDIX System as craft.
2. Type reset system shutdown. Press
Enter
once.
NOTE:
Do not press
Enter
again. This will force the AUDIX to shutdown
immediately, dropping all active calls on the AUDIX.
3. The “SHUTDOWN Completed” message appears when the AUDIX is
successfully shutdown. This takes about 2 minutes.
4. The AUDIX System can now be removed for service.