DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN
555-233-121
Issue 2
November 2000
SREPN Maintenance
2-11
SREPN connections
2
Figure 2-7
shows the hardware connections in the DS1-CONV system.
Figure 2-7.
Detailed SRP DS1-CONV connections
Figure Notes:
1. Fiber transmit (TX) and receive (RX)
pairs for A and B carriers.
2. SRP AUX B25A 25-pair cable; max.
length = 50 ft (15 m):
■
Major SRP power failure alarm lead
■
Remote restore signal leads
3. TN2301 - SRSwitch B25A 25-pair
cable; max. length = 50 ft (15 m):
■
-48V from SREPN through wall field
■
SRSwitch -48V power failure alarm
lead
■
SRSwitch signal leads
4. SREPN AUX connector B25A 25-pair cable; max.
length = 50 ft (15 m). Refer to the
Chapter 1
:
■
-48V to SRSwitch through wall field
■
SRP Alarm
■
SRSwitch signal leads
5. TN1654 (DS1C) can be used only in combination
with another TN1654.
6. Fiber transceivers (9823A - multimode)
7. 14-in. (36 cm) Y-Cable (Comcode 848101440)
8. Fiber optic cable pairs
9. Release 9r switch
cydfsrn2 KLC 011199