Note:
Additional side clearance is required for
service.
• top: 75 mm (3 in.)
Weight of fully loaded system with
• two SCSI hard drives
• six populated boards
• CD-ROM drive
• floppy drive
• tape drive
approximately 22 kg (46 lb)
Environmental specifications
Environmental condition
Specification
Operating temperature
10°C to 35°C (50°F to 95°F)
Maximum rate of change must not exceed
10°C (50°F) per hour.
Non-operating (storage) temperature
-40°C to 70°C (-40°F to 158°F)
Non-operating humidity
95%, non-condensing at 30°C (86°F)
Altitude
1829 m (6000 ft)
Electrostatic discharge
15 kV or more
Acoustic noise
50 dBA in a typical office ambient
temperature (18°C to 25°C [64.4°F to 77°F])
Operating shock
No errors with a half sine wave shock of 2G
(with 1 millisecond duration)
Handling drop
Operational after a free fall from 450 mm to
600 mm (18 in. to 24 in.) (depending on
weight)
Front panel features
The following diagram shows the 703t server's front panel features:
703t server description
10 Avaya CallPilot® 703t Server Hardware Installation