9012FC I/O cooling module
The Virtual Services Platform 9012 requires two 9012FC I/O cooling modules for first generation I/O
modules. You must install the I/O cooling modules in the front of the chassis. The I/O cooling
modules provide cooling for the interface modules and the Control Processor (CP) modules. Each
I/O cooling module includes eight fans.
Important:
• You must use the 9012FCHS cooling module if you install and configure second generation
modules; otherwise, the second generation modules remain offline until you install the
9012FCHS cooling modules. For more information about the 9012FCHS cooling module, see
• The CP monitors the temperature for each module. If the temperature exceeds the software set
limit, the CP shuts down only the affected module.
The I/O cooling modules are hot swappable. You can replace them, one at a time, without turning off
the Virtual Services Platform 9000.
The following figure shows the cooling module for the Virtual Services Platform 9012.
Virtual Services Platform 9012
March 2015
Installing Cooling Modules in Avaya VSP 9000
25