All equipment manufactured by Avantco is for use with the type of gas specified on the rating plate

and for installation that will be in accordance with National Fuel Gas Code ANSI Z223.1 (latest edition).

Instructions to be followed in the event the user smells gas must be posted in a prominent

location in the kitchen area. This information shall be obtained from the local gas supplier.

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

This equipment is design engineered for commercial use only.

Manual Griddles:

Radiant Charbroilers:

Hot Plates:

177AG24MG • 177AG36MG • 177AG48MG

177AG24RC • 177AG36RC • 177AG48RC

177AGR212 • 177AGR424 • 177AGR636

FOR YOUR SAFETY:

 Do not store or use gasoline or other flammable vapors 

or liquids in the vicinity of this or any other appliance.

WARNING:

 Improper installation, adjustment, alteration, service or 

maintenance can cause property damage, injury or death. Read the installation, 

operating and maintenance instructions thoroughly before installing or 

servicing this equipment.

Содержание 177AG series

Страница 1: ...ined from the local gas supplier PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE This equipment is design engineered for commercial use only Manual Griddles Radiant Charbroilers Hot Plates 177AG24MG 177AG36MG 177AG48MG 177AG24RC 177AG36RC 177AG48RC 177AGR212 177AGR424 177AGR636 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other app...

Страница 2: ...valve must be installed in the gas supply line ahead of the appliance and gas pressure regulator for safety and ease in servicing The gas pressure regulator supplied must be installed on the appliance prior to connecting the equipment to the gas line Failure to install a regulator could be potentially hazardous and will void the appliance warranty The appliance and its individual shut off valve mu...

Страница 3: ...mbination waste products released to the outside of the building The usual practice is to place the appliance under an exhaust hood which should be constructed in accordance with local codes Strong exhaust fans in this hood or in the overall air conditioning system can produce a slight vacuum in the room and or cause air drafts either of which can interfere with the pilot or burner performance and...

Страница 4: ...LP gas and all connections must be tested with a soapy water solution before lighting any pilots INITIAL PILOT LIGHTING Check all gas connections for leaks with a soapy water solution before lighting any pilots LIGHTING SHUTDOWN BEFORE GRIDDLES 1ST USE Turn all valves to the OFF position Wait for 5 minutes Turn pilot valve s by adjusting the screw counter clockwise then light standing pilot and ad...

Страница 5: ...ear water 5 Re oil with shortening or liquid frying compound 6 DO NOT FLOOD A HOT GRIDDLE WITH COLD WATER This could cause warping and the griddle plate to crack STAINLESS STEEL All stainless steel body parts should be wiped regularly with hot soapy water during the day and with a liquid cleaner designed for this material at the end of each day DO NOT USE steel wool abrasive cloth or powders to cl...

Страница 6: ...e valve on the front panel 1 Remove the trivets from the top of the appliance 2 Remove the burner from the top of the gas pipe 3 Replace the orifice fittings into the valve Note Unit Number on side of orifice fittings Orifice Fittings Plastic Insert Regulator with Brass Cap L P Position of Insert 4 Install the front panel knobs 5 Before installing the regulator unscrew the octagonal cap up you can...

Страница 7: ...4 35 000 140 000 36 L P Gas 10 35 000 140 000 50 177AG24MG 2 Independent Natural Gas 4 30 000 60 000 37 L P Gas 10 30 000 60 000 51 177AG36MG 3 Independent Natural Gas 4 30 000 90 000 37 L P Gas 10 30 000 90 000 51 177AG48MG 4 Independent Natural Gas 4 30 000 120 000 37 L P Gas 10 30 000 120 000 51 177AGR212 2 Independent Natural Gas 4 25 000 50 000 43 L P Gas 10 25 000 50 000 53 177AGR424 4 Indep...

Страница 8: ...Page 8 177AGR212 DIAGRAM ...

Страница 9: ...Page 9 177AGR424 DIAGRAM ...

Страница 10: ...Page 10 177AGR636 DIAGRAM ...

Страница 11: ...Page 11 177AG24MG DIAGRAM ...

Страница 12: ...Page 12 177AG36MG DIAGRAM ...

Страница 13: ...Page 13 177AG48MG DIAGRAM ...

Страница 14: ...Page 14 177AG24RC DIAGRAM ...

Страница 15: ...Page 15 177AG36RC DIAGRAM ...

Страница 16: ...Page 16 177AG48RC DIAGRAM ...

Страница 17: ...y to the installation and operating instructions Equipment damage or equipment failure due to improper installation improper utility connection or supply and problems due to ventilation Equipment that has not been used appropriately or has been subject to misuse neglect abuse accident alteration negligence damage during transit delivery or installation fire flood or act of God Equipment that has t...

Отзывы: