Instructions and user manual ChloriProtect
NOT004ENV05
5
3.3 Mounting of the probe on the probe holder
After removing the protective cap from the electrode and calibrate the probe (Cf 6.3), you need to insert all
the parts as shown in the fig.7. When all parts are engaged, tighten the nut without blocking it then push
slowly the electrode to the bottom of the hose and lift it about 2 cm so that the electrode tip is at the middle
of the hose. Connect the probe to the back of the device on the BNC (fig.8).
3.4 Electrical connection
3.4.1 Connection of the device in the electric casket
The power supply cable of ChloriProtect must be connected in the electric case of the swimming pool:
-
Either on the borders of an auxiliary contact in the relay of the pump of filtration in the electric
casket
-
Either on borders in parallel of the reel A1 A2 of the relay of the pump of filtration in the electric
casket
The tension to be applied to this cable is 230V-240V. So the device will be only fed when the pump of
filtration will be underway.
On no account the device will be connected in parallel on the borders of supply of the pump of filtration
in the electric casket
.
Fig. 6
Bracket
O-ring
Washer seat
Disk brake
A nut
Fig. 7
Plug the plug into the
bayonet socket
Rotate the plug ¼ turn to
close the connection
Fig. 8.1
Fig. 8.2