The  electrical  installation  to  which  the  device  is  connected  must  comply  with  the  standards  and  good 
practice rule in force in the country under consideration. 
Use of electrical equipment always implies observance of some basic rules. In particular:  
- Do not touch with wet or damp hands or feet. 
- Do not operate the device with bare feet (typical place: swimming pool) 
- Do not leave the equipment exposed to the atmospheric agents 
- Do not allow the device to be used by children or unskilled individuals without supervision 
•  The  device  must  be  supplied  through  a  circuit  with  a  residual  current  differential  device  (RCD)  rated 
differential operating current not exceeding 30 mA 
• The appliance must be placed in a place that can not be flooded. 
•  The  appliance  must  be  connected  electrically  via  a  means  of  disconnection  to  the  supply  network,  the 
opening  of  the  contacts  of  all  the  poles  ensuring  a  complete  break  under  the  conditions  of  overvoltage 
category III. 
• The power supply is protected by a thermal fuse T315 mA 250V. 
• The auxiliary output is protected by a fuse F2: T 3.15 A 250V. 
In  case  of  breakdown  or  improper  functioning  of  the  device,  switch  off,  but  do  not  touch.  Contact  our 
technical assistance for any necessary repairs and insist on the use of original spares. Failure to respect this 
condition could render the device unsafe to use. 
• For Australia and New Zeland Only, For stationary appliances permanently connected to the fixed wiring, 
compliance  with  this  requirement  is  considered  to  be  met  if  the  instruction  considering  disconnection 
incorporated in the fixed wiring is in accordance with AS/NZS 3000. 
• In case of damage of power supply cord please ask the repair to our technical assistance or qualified and 
authorized personnel, to avoid any hazard. 
When  you  decide  to  make  no  further  of  an  installed  device,  make  sure  to  disconnect  it  from  the  power 
supply. Before carrying out any service on the item, check to disconnect the plug from the mains. 

  1.5 - TOXIC AND/OR DANGEROUS LIQUID DOSAGE  

To  avoid  risk  from  contact  with  hazardous  liquids  or  toxic  fumes,  always  adhere  to  the  notes  in  this 
instruction manual: 
• Follow the instructions of the dosing liquid manufacturer 
• Use only the correct materials fir the tubing, valves and seals to suit the liquid to be dosed (if you use liquid 
regulation): where possible shield the tubing with PVC conduit. 

  1.6 - ASSEMBLING AND DISMANTLING THE DEVICE  

1.6.1 -ASSEMBLY  

See paragraph 

3.0 “INSTALLATION AND RECOMMENDATION”

 

1.6.2 - DISMANTLEMENT  

Proceed as follows when you dismantle the device or before performing any operation on it: 
1)  Disconnect the plug from the mains. 
2) See paragraph 

1.2 “SHIPPING AND TRANSPORTING”

 

 

Содержание ChloriProtect Rx

Страница 1: ...www avadypool com ChloriProtect Rx NOT004ENV05 INSTRUCTIONS AND USER MANUAL...

Страница 2: ...DEVICE 3 2 1 Parts description 3 2 2 Buttons description 3 3 0 INSTALLATION AND RECOMMENDATION 4 3 1 Installation of the fixing bracket 4 3 2 Mounting of the clamp 4 3 3 Mounting of the probe on the...

Страница 3: ...loriProtect NOT004ENV05 4 5 Adjustment of the set point 7 5 0 ALARMS ALR 7 6 0 MAINTENANCE 8 6 1 Maintenance of the electrode 8 6 2 Electrode wintering 8 6 3 Calibration procedure 8 7 0 AFTER SALES SE...

Страница 4: ...ipt Return of device or other materials to us or the authorized distributor must be agreed beforehand with the responsible personnel Material should be disassembled and packed with care All parts in c...

Страница 5: ...for any necessary repairs and insist on the use of original spares Failure to respect this condition could render the device unsafe to use For Australia and New Zeland Only For stationary appliances p...

Страница 6: ...rinator 2 1 Parts description Here are the complete content of the package you received All parts will be necessary for the proper operation of your device A Shutter B Buffer solution 475mV C Rx elect...

Страница 7: ...force in the various countries as regards of electrical installations For Australia and New Zeland the rules references are in accordance with AS NZS 3000 3 1 Installation of the fixing bracket 3 2 Mo...

Страница 8: ...e in the electric casket The power supply cable of ChloriProtect must be connected in the electric case of the swimming pool Either on the borders of an auxiliary contact in the relay of the pump of f...

Страница 9: ...vice is on a quick press on the ON OFF button turns off the device Alike when the device is off OFF is displayed A quick press on the ON OFF button turns on the device The device will start after 15 m...

Страница 10: ...red value 610 mV Switch on the salt water chlorinator 4 4 Manual supply of the electrolyser with salt 4 5 Adjustment of the set point 5 0 ALARMS ALR The alarm bustles when the value redox is lower tha...

Страница 11: ...to change the buffer solution if you have a doubt on its quality after several uses or after the expiry date 6 2 Electrode wintering During the wintering the electrode must be removed of the installa...

Страница 12: ...thout touching the electrode or the cable 4 After waiting minimum one minute the stabilized value is displayed Press CAL until the display shows CAL flashing then release Then the quality of the probe...

Страница 13: ...with the product when purchased new 8 0 SPARE PARTS LIST Fig 12 Code Description of parts 1 AYAC100167 Bracket 2 AYAC100021 BNC 3 AYAC100161 Auxiliary plug C13 4 AYAC100164C Circuit board ChloriProtec...

Страница 14: ...Y POOL 9 Chauss e Jules C sar B timent 4 Hall 406 95520 OSNY France T l 33 0 1 34 48 16 03 Fax 33 0 1 78 76 73 95 Mail contact avadypool com Site www avadypool com Installation and operating instructi...

Страница 15: ...Y POOL 9 Chauss e Jules C sar B timent 4 Hall 406 95520 OSNY France T l 33 0 1 34 48 16 03 Fax 33 0 1 78 76 73 95 Mail contact avadypool com Site www avadypool com Installation and operating instructi...

Страница 16: ...Y POOL 9 Chauss e Jules C sar B timent 4 Hall 406 95520 OSNY France T l 33 0 1 34 48 16 03 Fax 33 0 1 78 76 73 95 Mail contact avadypool com Site www avadypool com Installation and operating instructi...

Отзывы: