16
Motorized Home Storage Solution Model 1400/1600
The maximum running time until the motors overheat is usually depending on the load and is
3 minutes.
When the motors are overheated they take about 15 minutes to cool down and both of the
motors are stopped. After the motors are cooled down the operation can be continued.
When you push button
1
on the remote for example to raise the lift and you want the change
the direction when lift is moving, you can push button
3
and the lift will immediately change
the direction. By pushing button
3
the lift will be raised.
Only the original manufacturer’s replacement parts should be used for repair.
Make sure when you move the lift all the way to the top to wait for both motor’s to stop
turning. Sometimes they will readjust themselves when reaching the top.
Daily Inspection Instructions
1. Check the cables for damage. Are there any deformations, discoloration, cracks?
If there are any problems call customer service.
2. Is the storage-lift still evenly loaded or did any storage items move. If items are not
even distributed please move them so they weight is more evenly loaded.
3. Are the rope clips on both sides tight? Are the rope benders still tight?
If not tighten them with a wrench and a hexagon key.
4. Try to pay attention to the sound of the lift during operation. Are the motors working
correctly? Are they making unusual sounds? Do there seem to be any problems during
the raising and lowering of the lift? If you sense any problems please call customer
service.
5. Check out the struts that are attached to the garage ceiling. Did they move?
If so call customer service.
6. Please make sure there is a fully-charged battery in the remote.
7. Please check if the cables are overlapped. If so lower the lift all the way to the ground
and raise it back up. The cables should be not overlapped anymore. If problem
consists please call customer service.