AV-WALL-DT4oB
User’s manual
v1.1
Page
5
/
26
2
AV-WALL-DT4oB Quick Start
2.1
Power to Start-up
To start your AV-WALL-DT4oB, connect the RJ45 port to an active POE device using a
CAT5E/6 cable (100Mb/s connection).
When powered, the 6 White led lights on the AV-WALL-DT4oB front face will flash and then
the lights will flash alternatively until the device is switched on.
2.2
Connect the AV-WALL-DT4oB to an IP/Dante network
The connection of your AV-WALL-DT4oB to the IP/Dante network is done via the same
Ethernet CAT5e/6/7 cable used for the power supply.
AV-WALL-DT4oB has a unique IP network addresses and a unique name to control Dante
and AV-WALL-DT4oB settings:
The IP address is preset by default at factory to be set automatically using a DHCP
server or using APIPA address (169.254.xxx.xxx/16) if no DHCP server is detected
by the device. The IP address can be fixed using the Dante controller
The AV-WALL-DT4oB
name is preset at factory at “
AV-WALL-#
” where # is its serial
number. The Dante name of an AV-WALL-DT4oB can be changed by the Dante
Controller.
AV-WALL-DT4oB se
rial number 145 has Dante name “
AV-WALL-145
” as factory
preset
The AV-WALL-DT4oB setting can be done locally via the front face rotative button of
the
AV-WALL-DT4oB
or
via
AVSMonitor
(Software
downloadable
on
www.auvitran.com)