background image

 

 

P. 8 

Installation Guide

0

 

4 Quick 

Doors unlocked by transmitter with an intrusion occurred before 
unlocking the doors. 

5 Quick 

New 

transmitter 

programmed 

Quick  Unit reset: Occurs when the unit is reset to factory defaults 

 
Closing Up 

Use tie-wraps or screws to properly secure the starter Module and keep the wiring away from any moving parts 
such as the Parking Brakes or Steering Column Shafts. Mount all switches in good and accessible locations 
where they do not risk getting kicked or hit accidentally. 
Most comebacks are the result of misunderstandings about how a product works or performs. Take the time to 
properly explain all functions and features to the customers before they leave the premises. Doing this will save 
time and money. 
Always make all your connections before plugging in the Module, and be sure to test all functions properly 
before closing up the installation. 

Содержание ASL-300

Страница 1: ...e 7 Diagnostics Parking Lights Flash Rate 7 Closing Up 8 Included in the Kit Please review the installation guide before beginning the installation especially the wiring diagram and the programming op...

Страница 2: ...rammable features are as follows 1 Siren or OEM Horn Output The system can be programmed either to control the OEM horn or to command an external high power siren 2 Siren Horn Chirp Timing This featur...

Страница 3: ...ted by Default 5 WHITE RED SIREN OUTPUT This wire will give a positive output when an alarm intrusion has occurred It will also give positive pulses when remotely locking or unlocking the system Siren...

Страница 4: ...the first transmitter in memory will be lost To erase all transmitters from memory perform a module reset Proceed as follows to program a new transmitter 1 Flash the hood pin see above the parking li...

Страница 5: ...OPTION 1 Constant while button is pressed OPTION 2 Toggle ON Toggle OFF OPTION 3 60 second pulse OPTION 4 1 second pulse with Unlock pulse and Disarm pulse OPTION 5 1 second pulse with Disarm pulse O...

Страница 6: ...To adjust the timings for the Horn select MODE 2 FUNCTION 4 OPTION 3 or 4 The siren horn chirp duration can be configured by following these steps 1 Flash the hood pin switch see on page 4 the parking...

Страница 7: ...of a 2nd zone disable requires an external relay not included Multi car Operation This allows the user to control two systems with one transmitter Both vehicles must be equipped with identical module...

Страница 8: ...such as the Parking Brakes or Steering Column Shafts Mount all switches in good and accessible locations where they do not risk getting kicked or hit accidentally Most comebacks are the result of mis...