Time limits 
exceeded 

Time limit for 
autonomous operation 
of the heater is 
achieved (with applied
setting 1.1)

Run the engine or cancel 1.1 
setting

5

Unsuccessful 
start

The heater was 
switched off 
spontaneously at 
startup 

Make diagnostics of the heater 
if the error appears again

6

Operation 
cycle too 
short 

The heater was 
switched off 
spontaneously with 
operating time of less 
than 20 minutes

Make diagnostics of the heater 
if the error appears again

8

CAN-bus 
error

The lines X2.9 и X2.10 
connected incorrectly

Check the lines connection 

9

Settings error Settings have been 

incorrectly stored in 
RCP’s memory

Reset the settings (8.1.1), 
readjust RCP 

11

Heater no 
connection 

The heater is 
unplugged from CAN-
bus or is out of order

Make diagnostics of the heater

12

Unknown 
CAN-bus

CAN-bus type has not
been determined 

Check for compatibility of RCP 
module with the car. Try to set 
the CAN-bus code manually*

* Information available on request

© Autoplugin ES        

www.autoplugin.ru

Содержание RCP-V2

Страница 1: ...Autoplugin RCP V2 Installation Manual Rev A...

Страница 2: ...Blue Additional devices control Brown white Green Green yellow Autoplugin RCP V2 Red white Feedback to remote control to scheme of turning off Blue Grey Brown Outer indicator to scheme of turning on f...

Страница 3: ...r the heater remote start by using Volvo key turn on perimeter lighting then press Lock button twice Find place under the dashboard for the module and fix it with adhesive tape Shorten length of the c...

Страница 4: ...ive polarity Green Blue X1 3 4 to RC RCP Ground X1 3 4 Battery to RC Green Blue RCP Figure 2 Figure 3 o The fig 4 presents the scheme to turn the heater off by the impulse of positive polarity The fig...

Страница 5: ...Easy Start Webasto Telestart If direct connection of remote control s output line to the input RC_in is not functional the scheme at the fig 7 can be applied 85 86 30 87 to X1 7 of RCP Can to RC Rela...

Страница 6: ...o be adjusted for this purpose 3 Installation procedure for permanent connection General recommendations The required tools Torx screwdriver wire cutter wire stripper Remove the panel around the servi...

Страница 7: ...possible solutions Table 1 Error Code Error Description Possible Reasons of Error Appearance Solutions 2 No answer from the heater followed the start command The heater is not activated in the CIP Con...

Страница 8: ...20 minutes Make diagnostics of the heater if the error appears again 8 CAN bus error The lines X2 9 X2 10 connected incorrectly Check the lines connection 9 Settings error Settings have been incorrect...

Отзывы: