8
4
Time limits
exceeded
Time limit for
autonomous operation
of the heater is
achieved (with applied
setting 1.1)
Run the engine or cancel 1.1
setting
5
Unsuccessful
start
The heater was
switched off
spontaneously at
startup
Make diagnostics of the heater
if the error appears again
6
Operation
cycle too
short
The heater was
switched off
spontaneously with
operating time of less
than 20 minutes
Make diagnostics of the heater
if the error appears again
8
CAN-bus
error
The lines X2.9 и X2.10
connected incorrectly
Check the lines connection
9
Settings error Settings have been
incorrectly stored in
RCP’s memory
Reset the settings (8.1.1),
readjust RCP
11
Heater no
connection
The heater is
unplugged from CAN-
bus or is out of order
Make diagnostics of the heater
12
Unknown
CAN-bus
CAN-bus type has not
been determined
Check for compatibility of RCP
module with the car. Try to set
the CAN-bus code manually*
* Information available on request
© Autoplugin ES
www.autoplugin.ru