4.2
Autopilot Settings
VS target
is the target vertical speed, when change in the elevation is re-
quired. This speed shall be smaller than max vertical speed from the
limits, section 4.2.3.
Max pitch rate
tells how quickly pitch reference can change.
Controller
loops are calculated several times per second and they change their
desired
pitch all the time. If the outer loop – vertical speed control
loop asks for a quick change in pitch, the controller will limit the speed
of change to the value entered here. The airplane will therefore make
a smooth transition.
Max roll rate
tells how quickly roll reference can change. Same as above,
but now for the roll angle. If the outer loop – heading control loop asks
for a quick change in roll, the controller will limit the speed of change
to the value entered here. The airplane will therefore make a smooth
transition.
Max VS rate
is the rate of change of the target vertical speed (it has dimen-
sion of acceleration). Similar as above, but now for vertical speed.
Turn comp
defines amount of elevator compensation that is required when
airplane is executing a turn. Pitch will be slightly increased during the
turn. The increase grows with the roll angle.
Roll rate gain
Value 0.9 is special and it means that Roll rate gain mode
is disabled.
4.2.5
Tuning
Tuning is a in-flight operation. This operation is quite complex and is based
on
trial and error
. Here only window description is given. Please refer to the
section 5.5 for details about the tuning procedure.
When the
Tuning
option is selected from the Autopilot menu, a window il-
lustrated on Figure 11 appears. Select one of four autopilot control loops to
tune.
24
©