background image

-|Transparent Guide|-

DRW190758AD

Safety Controllers / 

Safety Relay Unit

SFC / SFC-R Series

For your safety, read and follow the considerations written in the instruction 
manual, other manuals and Autonics website.

The specifications, dimensions, etc. are subject to change without notice for product 
improvement. Some models may be discontinued without notice.

ᜢ ᜩ ᜦ ᜪ

Major Features

• 

Slim size (17.5 / 22.5 / 35 mm) for saving installation space 

• 

Various LED indicators for displaying status (power / input / logic input / error / 
feed back / output)

• 

Screw / Screwless connection models 

• 

P channel FET / Relay contact safety output models

• 

Available off-delay output and time setting (advanced/non-contact door switch/relay 
output models)

• 

Available logic (AND) connection and extension relay unit connection (advanced/non-
contact door switch models)

• 

The product structure conforms with international safety regulations and standards 
: SIL3, SIL CL3, PLe, CE, UL Listed, and S Mark

Safety Considerations

• 

Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.

• 

᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01.  Fail-safe device must be installed when using the unit with machinery that may 

cause serious injury or substantial economic loss. (e.g. nuclear power control, 

medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, 

safety equipment, crime/disaster prevention devices, etc.) 

Failure to follow this instruction may result in personal injury, economic loss or fire.

02.  Responsible person for use is an operator who:

 

- is fully knowledgeable about the installation, settings, use and maintenance of 

the product

 

- is familiar with the requirements of laws, regulations and standards in the 

country or region where the product is installed and used. 

Responsible person for use has an obligation to educate the requirements to 

machine users.

 

Machine users are persons who have been fully trained by the responsible person 

for use and can operate the machine correctly. When any error occurs during the 

operation of the machine control system, they have a responsibility to report it to 

the responsible person for use immediately.

If an unqualified person operates the product, it may result in personal injury, economic 

loss or fire.

03.  Qualified personnel shall carry out installation, configuration and combination 

with the machine control system.

If an unqualified person carry out installation, configuration and combination with the 

machine control system, it may cause malfunction or result in accidents.

04.  When the connected devices (e.g., motor) is not operating after installation, check 

that functions and settings of the product correctly operate as you intended.

Failure to follow this instruction may result in personal injury, economic loss or fire.

05.  Be sure to consider the delay of the safety output when determining the safety 

distance to the hazardous source due to the response time (safety input and logic 

input), setting of off-delay time and off-delay time accuracy. 

The machine may not stop before an operator reaches the hazardous zone so that it may 

result in personal injury and economic loss.

06.  Do not use the unit in the place where flammable/explosive/corrosive gas, high 

humidity, direct sunlight, radiant heat, vibration, impact, salinity, moisture, or 

steam, or dust may be present.

Failure to follow this instruction may result in explosion or fire.

07.  Do not disassemble or modify the unit.

Failure to follow this instruction may result in personal injury or fire. In addition, the 

manufacturer does not guarantee the performance and functionality.

08.  Do not connect, repair, inspect, or replace the unit while connected to a power 

source.

Failure to follow this instruction may cause the external devices connected to the product 

may unexpectedly operate. For more information, please refer to laws, regulations and 

standards in the country or region.

09.  Install the product on a device panel or DIN rail inside the control room with IP54 

or higher protection structure.

Failure to follow this instruction may result in fire or electric shock.

10.  When using the product mounted on a DIN rail, fix it using an End plate (sold 

separately).

Failure to follow this instruction may result in fire or electric shock.

11.  When you use the product in a place where vibrations or shocks are very high, use 

screws to fix it to the panel for use.

Failure to follow this instruction may result in personal injury and fire.

12.  Check ‘Connections’ before wiring. And make sure that there are no safety 

problems.

Failure to follow this instruction may result in fire.

13.  You must conduct daily and regular inspections every six months.

Failure to follow this instruction may result in personal injury, economic loss or fire due to 

the malfunction of the product.

14.  The auxiliary output is non-safety output, therefore, do not use it for safety 

purposes.

Failure to follow this instruction may result in personal injury, economic loss or fire.

15.  This product is designed to comply with industrial environment A. Use of this 

product in residential environment B may cause unwanted electromagnetic 

interference. In this case, it requires to take appropriate mitigation measures.

Содержание SFC Series

Страница 1: ...th the machine control system it may cause malfunction or result in accidents 04 When the connected devices e g motor is not operating after installation check that functions and settings of the product correctly operate as you intended Failure to follow this instruction may result in personal injury economic loss or fire 05 Be sure to consider the delay of the safety output when determining the s...

Страница 2: ... voltage Power consumption 01 2 5 W 3 0 W 3 5 W Input ON 11 VDCᜡ 5 mA OFF 5 VDCᜡ 1 mA Input time 50 ms feedback start manual 100 ms Cable 100 m 100Ω 10nF Safety output P channel FET 02 Instantaneous 4 3 03 3 03 Off delay 04 2 03 2 03 Time accuracy 5 5 Load current Below 2 point output DC 1 A Over 3 point output DC 0 8 A Leakage current 0 1 mA Operating time OFF ON 05 Safety input 50 ms Logic input...

Страница 3: ...tors Model SFC SFC A SFC N SFC ER SFC R 12 SFC R212 R2 PWR green Power M1 white Safety input 1 ㅡ M2 white Safety input 2 ㅡ NS white Non contact door switch input ㅡ ㅡ ㅡ ㅡ ㅡ AND white Logic input ㅡ ㅡ ㅡ ㅡ ERR red Error FB white Feedback start input ㅡ OUT1 green Instantaneous safety output OUT2 green Off delay safety output ㅡ ㅡ ㅡ Installation Mounting with bolts 1 Pull each rail locks to up and down a...

Страница 4: ...F state The duration that the start switch is in the ON state min 100 ms Feedback loop Start switch 24 VDCᜡ M61 M62 Logic input Connect the safety outputs of the upper unit to the logic AND input of the lower unit To use the logic input function SW1 and SW2 of switch for setting function must be set to ON state Up to four units advanced non contact door switch unit can be connected as logic AND co...

Страница 5: ...tting value of the switch for off delay time Flash Error at internal circuit and output relay of the expansion relay unit Please contact the Autonics OFF M1 M2 flashes The different input signal between safety input 1 and safety input 2 Check the wiring to the safety input devices Check the input sequence of safety inputs CheckandMaintenance Check installation conditions Checklist Check 1 The dist...

Страница 6: ...9 e 4 218 18 year 99 00 SFC A322 23 L SFC A322 2300 4 99 00 SFC A322 2300 L SFC N SFC N322 23 SIL 3 7 36E 09 e 4 183 67 year 99 00 SFC N322 23 L SFC N322 2300 4 99 00 SFC N322 2300 L SFC R SFC R212 SIL 3 5 29E 09 e 4 247 78 year 99 00 SFC R212 L SFC R412 4 99 00 SFC R412 L SFC R212 R23 4 99 00 SFC R212 R23 L SFC R212 R230 4 99 00 SFC R212 R230 L FailureRate ...

Страница 7: ...1 Safety Input 2 Feedback Start Input Auxiliary Output Logic Input Safety Output SW1 Safety light curtain MC1 to MC4 Contactor M1 M2 3 phase motor Motor Controller Control Signal Motor Controller Operation timing chart MC3 MC4 a contact MC3 MC4 b contact MC1 MC2 a contact MC1 MC2 b contact Safety light curtain SW1 Motor controller control signal Rotation of M2 motor Off delay time For more informa...

Страница 8: ...ntroller Advanced unit Power Expansion Output Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Logic Input Safety Output PLC etc Motor controller Motor Controller Control Signal Expansion Output Expansion Input Power Auxiliary Output Safety Relay Output Safety controller Expansion relay unit PLC etc SW1 Lock release switch SW2 Safety door lock switch SW3 Safety limit switch SW4 ...

Страница 9: ... Input Safety controller Non contact door switch unit PLC etc Motor Controller Actuator SFN Series Safety Non Contact Door Switch White Black Brown Blue Motor Controller Control Signal SW1 Lock release switch SW2 Safety door lock switch SW3 Safety limit switch SW4 Safety emergency stop switch SW5 Safety non contact door switch MC1toMC2 Contactor M1 Motor Operation timing chart M1 Rotation of motor...

Страница 10: ...Start Input Auxiliary Output Logic Input Safety Output Expansion Output Non Contact Door Switch Input Safety controller Non contact door switch unit PLC etc Actuator SFN Series Safety Non Contact Door Switch White Black Brown Blue Motor Controller Control Signal PLC etc Operation timing chart Safety controller Basic unit Safety controller Non contact door switch unit Start switch SW2 Safety emerge...

Страница 11: ... Safety controller Relay unit Feedback Start Input Auxiliary Output Safety Relay Output Power Safety Input 1 Safety Input 2 PLC etc SW1 Safety emergency stop switch SW2 Start switch MC1 MC2 Contactor M1 3 phase motor Operation timing chart M1 Rotation of motor MC1 MC2 a contact MC1 MC2 b contact Safety emergency stop switch SW1 Start switch SW2 When you do not use the logic input M61 M62 set the s...

Страница 12: ...mitter SFL A Series Receiver OSSD1 OSSD2 NC NC 24V GND MC1 MC2 MC3 MC4 MC3 MC4 M2 MC3 MC4 MC1 to MC4 Magnetic contactor M1 M2 3 phase motor Safety controller Relay unit PLC etc Power Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Safety Relay Output Operation timing chart MC1 to MC4 b contact MC1 to MC4 a contact Safety light curtain For more information on wiring and detailed...

Страница 13: ...1 SW1 Unlock signal SW4 SW2 MC2 MC1 SW3 MC1 MC2 M1 MC1 MC2 GND GND 24V PLC etc SW1 Safety limit switch SW2 Safety door lock switch SW3 Feedback start switch SW4 Unlock switch MC1 to MC4 Magnetic contactor M1 M2 3 phase motor Safety controller Relay unit Off Delay Power Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Safety Relay Output Instantaneous Operation timing chart Off d...

Отзывы: