9. Serial Communication Commands
69
© Copyright Reserved Autonics Co., Ltd.
9. Serial Communication Commands
9.1
Communication condition
Communication conditions
Descriptions
Communication speed
9600 to 115200bps
Data bit
8 bit
Stop bit
1 bit
Flow control
None
Parity bit
None
Control character
0-9, A-Z,
(Space), [CR] (Carriage return)
9.2
Command Cycle
(1)
means a space�
(2) [CR] means 0x0d carriage return.
(3) [LF] means 0x0a line feed.
9.3 Command
PRG
It executes a program in the PMC-1HS/PMC-2HS from an assigned address.
Format
Command
[Axis specification] [REG number specification] [CR]
PRG
X
[CR]
Y REG number (decimal)
Put the axis specification "X" in PMC-1HS.
[Example] To operate X/Y-axis from REG00
PRG
XY00 [CR]
Response: No-response
JOG
Start the continuous drive on the specified axis.
Format
Command
[Axis specification] [REG number specification] [CR]
JOG
+ X [CR]
- Y
Put the axis specification "X" in case of PMC-1HS.
[Example] To drive X-axis and Y-axis in the + and - directions respectively.
JOG
X
-
Y [CR]
The + direction can be omitted in the axis specification.
Response: No-response