Страница 3: ...lecting Autonics products Please familiarize yourself with the information contained in the Safety Precautions section before using this product This user manual contains information about the product and its proper use and should be kept in a place where it will be easy to access ...

Страница 4: ...be edited or reproduced in either part or whole without permission This manual is not provided as part of the product package Please visit our home page www autonics com to download a copy The manual s content may vary depending on changes to the product s software and other unforeseen developments within Autonics and is subject to change without prior notice Upgrade notice is provided through our...

Страница 5: ...Manual Symbols Symbol Description Supplementary information for a particular feature Failure to follow instructions can result in serious injury or death Failure to follow instructions can lead to a minor injury or product damage An example of the concerned feature s use 1 Annotation mark ...

Страница 6: ...instruction may result in personal injury fire or economic loss In case controlling other devices through Graphic Panel communication and there is a possibility of malfunction due to communication error an alternative circuit must be constructed Failure to follow this instruction may result in personal injury fire or economic loss Do not use the product in an area or an environment not specified i...

Страница 7: ... an area with excessive humidity or temperature Failure to follow this instruction may result in product damage or shortening the life cycle of the unit Do not close ventilating opening of this product Failure to follow this instruction may result in product damage due to increase inner heat Keep the product out of direct sunlight or excessive dust Failure to follow this instruction may result in ...

Страница 8: ...Safety Precautions 8 Copyright Reserved Autonics Co Ltd Note that this device is KCC certified for commercial use Make proper applications for the product ...

Страница 9: ...on and dimensions communication cable model C3M5P05 D9F0 D9M0 11 2 GP S070 Communication Setting 13 2 1 GP Editor Setting 13 2 2 GP S070 Setting 15 2 3 GX Works2 Setting 17 3 Examples 23 3 1 GP S070 Drawing 23 3 2 PLC Program 23 3 3 GP S070 PLC device connection 24 3 4 GP Editor Drawing 25 3 4 1 Numeral display 25 3 4 2 Numeral input 26 3 4 3 Touch key Up key 27 3 4 4 Touch key Down key 28 3 4 5 L...

Страница 10: ...Table of Contents 10 Copyright Reserved Autonics Co Ltd ...

Страница 11: ...ersion Note GP Editor V4 01 build 023 GP S070 Firmware V1 20 Release 2016 01 26 Ms Windows Windows 7 GX works2 V1 77F 1 2 Connections GP S070 T9D6 CPU Q02HCPU Communication card QJ71C24N 1 3 Communication cable connection and dimensions communication cable model C3M5P05 D9F0 D9M0 ...

Страница 12: ...1 System 12 Copyright Reserved Autonics Co Ltd ...

Страница 13: ...tion Setting 2 1 GP Editor Setting 1st Select Project New on menu If you have the saved file open the project at Load 2nd At GP PLC Type dialog box set GP LP Type and CH1 2 Group Type Item Setting GP LP Type GP S070 T9D6 CH1 Group Type MITSUBISHI Q SERIES QhighP_EXT_MC CH2 Group Type No Use ...

Страница 14: ...2 GP S070 Communication Setting 14 Copyright Reserved Autonics Co Ltd 3rd At Project Auxiliary Property dialog box click OK and it changes screen to draw ...

Страница 15: ...2 GP S070 Communication Setting Copyright Reserved Autonics Co Ltd 15 2 2 GP S070 Setting 1st Touch top left of the GP 2nd Touch Environment 3rd Touch Serial Communication ...

Страница 16: ...on set as below PROTOCOL PORT CH1 MITSUBISHI Q SERIES QHighP_EXT_MC RS 232C SET CH2 No Use RS 422 SET 5th Touch right SET and set as below Item Setting Note Baud rate 115200 User setting Flow control XON XOFF Don t care Parity bit ODD Fixed Data bit 8 bit User setting Stop bit 1 bit User setting ...

Страница 17: ...on Setting Copyright Reserved Autonics Co Ltd 17 2 3 GX Works2 Setting 1st Run GX Works2 and select Project New on menu Select project type PLC series type and language 2nd Select Intelligent Function Module and New Module ...

Страница 18: ...ight Reserved Autonics Co Ltd 3rd Set items as below Item Setting Note Module Type Serial Communication Modem Interface Module Module Name QJ71C24N Mounted Slot No 0 Installed slot number 4th Double click Switch Setting and set items as below ...

Страница 19: ...ata Bit 8 Fixed Parity Bit Exist Fixed Even odd parity Odd Fixed Stop bit 1 Fixed Sum Check code None Fixed Online Change Enable Don t care Setting modifications Enable Don t care Communication rate setting 1152000 bps User setting Communication protocol setting MC protocol Format1 Fixed Station number setting 1 User setting ...

Страница 20: ...nication Setting 20 Copyright Reserved Autonics Co Ltd 5th Select Connection Destination at Navigation tab and double click Connection1 6th Select connection method Click Connection Test and PLC Type displays Q02 Q02H ...

Страница 21: ...2 GP S070 Communication Setting Copyright Reserved Autonics Co Ltd 21 7th Select Online Write to PLC Click Select All and Execute ...

Страница 22: ...2 GP S070 Communication Setting 22 Copyright Reserved Autonics Co Ltd ...

Страница 23: ...3 Examples Copyright Reserved Autonics Co Ltd 23 3 Examples 3 1 GP S070 Drawing 3 2 PLC Program ...

Страница 24: ...device connection GP S070 PLC Device Item Tag Property Usage Bit Word Numeral display Counter present value D0 Numeral input Counter target value D1 Touch key momentary Input Up M0 Touch key momentary Input Down M1 Lamp Counter output M3 Touch key momentary Reset M2 ...

Страница 25: ...pyright Reserved Autonics Co Ltd 25 3 4 GP Editor Drawing 3 4 1 Numeral display Select Draw Numeral Display at menu Click Device to set the device as below Items Setting Channel CH1 QHighP_EXT_MC Station 1 Device D0 ...

Страница 26: ...3 Examples 26 Copyright Reserved Autonics Co Ltd 3 4 2 Numeral input Select Draw Numeral Input at menu Click Device to set the device as below Items Setting Channel CH1 QHighP_EXT_MC Station 1 Device D1 ...

Страница 27: ... Copyright Reserved Autonics Co Ltd 27 3 4 3 Touch key Up key Select Draw Touch Key Action Bit Click Device to set the device as below Items Setting Channel CH1 QHighP_EXT_MC Station 1 Device M0 Action Momentary ...

Страница 28: ...28 Copyright Reserved Autonics Co Ltd 3 4 4 Touch key Down key Select Draw Touch Key Action Bit Click Device to set the device as below Items Setting Channel CH1 QHighP_EXT_MC Station 1 Device M1 Action Momentary ...

Страница 29: ...3 Examples Copyright Reserved Autonics Co Ltd 29 3 4 5 Lamp Select Draw Lamp Click Device to set the device as below Item Setting Channel CH1 QHighP_EXT_MC Station 1 Device M3 ...

Страница 30: ...30 Copyright Reserved Autonics Co Ltd 3 4 6 Touch key Reset key Select Draw Touch Key Action Bit Click Device to set the device as below Item Setting Channel CH1 QHighP_EXT_MC Station 1 Device M2 Action Momentary ...

Страница 31: ...P S070 and GP Editor GP Editor is available only for CH1 serial port setting Item Setting at GP Editor Setting at GP S070 CH1 comm setting Avaliable Avaliable CH2 comm setting Unavailable Avaliable 1st Check the settings Application of serial port setup menu key configuration at Common Auxiliary Configuration Project ...

Страница 32: ...4 Appendix 32 Copyright Reserved Autonics Co Ltd 2nd At Serial Port tab set CH1 port configuration 3rd At Setup tab set CH1 port station settings For CH2 the left port is automatically alloted ...

Страница 33: ...4 Appendix Copyright Reserved Autonics Co Ltd 33 ...

Страница 34: ...4 Appendix 34 Copyright Reserved Autonics Co Ltd ...