 Specifications

※ 

The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.

BF5 Series                                   Fiber Optic Amplifier 

Please read “Caution for your safety” in operation

manual before using.

Dual digital display type fiber optic amplifiers

 Features

● Dual-display for light incident level and setting value(BF5 -D)
● Minute object sensing available with 1/10,000 high resolution

● Enables to detect with high-speed(20,000 times per sec.) moving objects

● 4 response speeds

   : Ultra fast mode(50

), high speed mode(150

),

     standard mode(500

), long distance mode(4ms)

● Long lasting amplifier regardless of element’s life degradation 

   or temperature change

● Multiple sensitivity setting modes available

   : auto tuning, 1 point(maximum sensitivity), 2 point, positioning teaching

● Up to 8 units enable to stack with mutual interference prevention function 

   using side connectors

● Auto channel setting function for multiple installations

● Slim design(W10×H30×L70mm)

M

od

el

Display type

Dual Display type 

Single Display type 

NPN open collector output

BF5R-D1-N 

BF5G-D1-N 

BF5B-D1-N 

BF5R-S1-N 

PNP open collector output

BF5R-D1-P 

BF5G-D1-P 

BF5B-D1-P 

BF5R-S1-P 

Light source

Red LED

(660nm, modulated)

Green LED

(530nm, modulated)

Blue LED

(470nm, modulated)

Red LED

(660nm, modulated)

Power supply

12-24VDC±10% 

Current consumption

Max. 50mA

Operation mode

Light ON / Dark ON Selectable

Control output

NPN or PNP open collector

●Load voltage: Max. 24VDC  ●Load current: Max. 100mA  ●Residual voltage

 -

 NPN:Max. 1V, PNP:Max. 3V

Protection circuit

Reverse polarity protection, overcurrent protection, surge absorption

Response time

Ultra Fast : 50

, Fast : 150

,STD : 500

, Long : 4ms Fast : 150

, STD : 500

, Long : 4ms

Display method

●Incident light level: Red, 4digit, 7Segment

●SV : Green, 4digit, 7Segment

●Main output indicator : Red LED

●Incident light level / SV : Red, 4digit, 7Segment

●Main output indicator : Red LED

Display function

Incident light level / SV display [4,000/10,000 resolution], Percentage display, High/Low peak value display,  

Normal / Reversed display

Sensitivity setting

Auto tuning, 1 point teaching,

2 point teaching, Positioning teaching

Auto tuning

Mutual interference

prevention

Max. 8 unit sets (Automatically set regardless of response time)

Initializing

Initializing to factory mode

-

Energy saving

Normal / Energy saving 1 / Energy saving 2

-

Timer

OFF, OFF Delay, ON Delay, One-shot

OFF, 10ms OFF Delay timer, 40ms OFF Delay timer

Insulation resistance

Min. 20MΩ(at 500VDC megger)

Dielectric strength

1,000VAC 50/60Hz for 1 min.

Vibration

1.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each X, Y, Z directions for 2 hours

Shock

500m/s

2

(Approx. 50G) in each X, Y, Z directions for 3 times

Environ-

ment

Ambient illumination Incandescent lamp : Max. 3000

 Sunlight : Max. 11000

 

Ambient temperature -10 to 50

, storage: -20 to 70

Ambient humidity 35 to 85%RH, storage: 35 to 85%RH

Protection

IP40(IEC standards)

Material

Case : PBT, Cover : PC

Fiber cable

Tightening torque

Min. 2kgf

Accessory

Connector type wire(ø4, 3-wire, 2m) (AWG22, Core diameter: 0.08mm, Number of cores: 60,

Insulator out diameter: ø1.25mm), Side connector

Approval
Unit weight

Approx. 20g

Line-up

PNP output model

Содержание BF5 Series

Страница 1: ...ed LED 660nm modulated Power supply 12 24VDC 10 Current consumption Max 50mA Operation mode Light ON Dark ON Selectable Control output NPN or PNP open collector Load voltage Max 24VDC Load current Max 100mA Residual voltage NPN Max 1V PNP Max 3V Protection circuit Reverse polarity protection overcurrent protection surge absorption Response time Ultra Fast 50 Fast 150 STD 500 Long 4ms Fast 150 STD ...

Страница 2: ...ide connector as the figure After mounting the unit on the DIN rail push gently both units to fasten each other Make sure that connections between the unit case and connectors correctly Improper connection may cause malfunction of channel setting and mutual interference prevention functions Do not supply the power while connecting disconnecting amplifier units Control output diagram NPN open colle...

Страница 3: ...sensitivity 3 PV display part 4 Digit Red 7 segments Used to indicate incident light level and parameters 4 SV display part 4 Digit Green 7 segments Used to indicate SV and setting data 5 Up down key Used to up down setting values Used to Fine adjusting sensitivity 6 MODE key Used to enter into program mode data Bank mode Used to move each parameter 1 12 2 3 4 7 PV SV display part 4 Digit Red 7 se...

Страница 4: ...le teaching is in the process If incident light level is received under 10 digit while teaching is in the process it is automatically returned to RUN mode and previous setting value is retained after ERRL flashes twice If there is no key operation for 60 sec after entering into teaching mode it is automatically return to RUN mode 1 Auto tune teach mode Suitable when incident level of sensing objec...

Страница 5: ...2950 1PNT will be flashing twice 0 5sec will be flashing 0 5sec during teaching flashes 0 5sec during teaching flashes 0 5sec during teaching SV will be flashing twice 0 5 sec and returned to RUN mode SV range for sensing distance Make sure that two point teaching must be done within 60 sec after one point teaching If not teaching mode is cancelled and it returns to RUN mode Response Time Teaching...

Страница 6: ... TCHI YES CH2 OK CH3 OK CH4 OK CH8 OK TCHI TCHI END TCHI END TCHI END TCHI END TCHI END TCHI TCHI TCHI TCHI When group teaching is executed the Master unit transmits teaching command to each Slave unit and channel No and OK is displayed Select NO and press key or key to return to RUN mode The Master unit starts teaching after teaching command transmission to Slave unit is completed GroupTeaching k...

Страница 7: ...ching is completed the Master unit flashes SV twice and displays TCHI on the PV display part and END on the SV display part Then they automatically return to RUN mode Program mode setting When entering into program mode parameters lights ON on the PV display part and setting values flashes every 0 5 sec on SV display part Use the keys to set each setting value Press the key one time after setting ...

Страница 8: ...mall sensing object 3 modes are available Timer Off OFF On Delay OND Delays control output ON time from OFF for a certain period of setting time Off Delay OFD Delays control output OFF time from ON for a certain period of setting time One shot SHOT Turns control output ON or OFF within a certain period of setting time Setting time TIME 1 to 5000ms Time chart Program mode function Timer OFF L O Tim...

Страница 9: ...settings for group amplifier units in each data Bank by using Master unit s command or by adjusting one amplifier unit s setting and to load required data Bank when it is necessary without resetting for each unit s parameters and setting values LOAD LOAD Loads preset dataBank BAK0 1 2 and applies it to the amplifier unit Detailed Bank parameters can be read and changed SAVE SAVE Saves one amplifie...

Страница 10: ...ey key key key key key key key key Bank2 Bank2 Bank 2 Bank 2 Bank1 Bank1 Bank 1 Bank 1 Bank0 Bank 0 Bank 0 Bank 0 1 1 copy 1 M copy Data load Data save Data copy Load all Save all 2 2 2 Press key to stop reading and changing each bank data Press key to load certain bank and to read change bank data DATA BANK COPY S S COPY S M LDAL NO COPY NO SVAL NO COPY END SVAL END SAVE END LDAL END COPY ALL LDA...

Страница 11: ...n the PV display part and END on the SV display part and they return to RUN mode When Load All is completed the Master unit displays LDAL on the PV display part and END on the SV display part Press the key to return to Load All mode While Save All is executed the Master unit displays the channel number on the PV display part and OK on the SV display part While Save All is executed the Slave units ...

Страница 12: ...IT parameter turns ON on PV display part and NO flashes every 0 5sec on SV display part Press the key once again to return to RUN mode without executing initializing Function Select YES using the keys and press the key INIT flashes twice on both PV and SV display parts When parameter initialization is completed it is automatically returned to RUN mode RUN mode RUN mode key Previous SV SV key key P...

Страница 13: ... not stable or moved fast One of teaching modes that sets the sensitivity using average value of the maximum and minimum incident light level within a certain time period Set_value P1 P2 Pn 1 Pn n Max Set Value Min Teaching section Over 3 sec 3400 3300 3200 3020 2700 2500 Time Incident light level Teaching is executed while pressing key Press key AUTO flashes twice every 0 5 sec 1 flashes during t...

Страница 14: ...equence Group teaching is executed after teaching command is transmitted form the Master unit Master unit RUN mode Flashes in turn every 0 5 sec Flashes twice every 0 5 sec Flashes twice every 0 5 sec Flashes twice every 0 5 sec Teaching SV flashes twice every 0 5 sec Flashes in turn every 0 5 sec Flashes in turn every 0 5 sec Slave unit RUN mode Press key 3sec Select YES and prss key to execute g...

Страница 15: ...ing time for each amplifier unit in case of adjacent fiber cable installations in order to prevent mutual interference occurring Set automatically when power is turned ON Mutual interference function is allowed up to maximum 8 amplifier units regardless of the unit model and response time High peak low peak function A function to monitor the high low peak value of incident light level The monitore...

Отзывы: