-|Transparent Guide|-

TCD210124AA

Built-in Gear / Rotary Actuator Type  
5-phase Stepper Motor  

(□ 42 mm, □ 60 mm, □ 85 mm)

AK-G / AK-R Series

PRODUCT MANUAL

For your safety, read and follow the considerations written in the instruction 
manual, other manuals and Autonics website.

The specifications, dimensions, etc. are subject to change without notice for product 
improvement. Some models may be discontinued without notice.

Features

• 

Ideal for building compact sized system

• 

Low price for improved cost efficiency

• 

Backlash □42mm : ±35'(0.58 ), □60mm : ±20'(0.33 ), □85mm : ±15'(0.25 )

• 

Brake releases when 24 VDC is applied on brake wire (AK-GB Series, AK-RB Series)

• 

Basic step angle 1:5 → 0.144 , 1:7.2 → 0.1 , 1:10 → 0.072

• 

Allowable speed 1:5 → 0 to 360 rpm, 1:7.2 → 0 to 250 rpm, 1:10 → 0 to 180 rpm

ᜢ ᜫ

Safety Considerations

• 

Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.

• 

᜸ symbol indicates caution due to special circumstances in which hazards may occur.

᜸ Warning

  

Failure to follow instructions may result in serious injury or death.

01. 

Fail-safe device must be installed when using the unit with machinery that may 

cause serious injury or substantial economic loss. (e.g. nuclear power control, 

medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, 

safety equipment, crime / disaster prevention devices, etc.)

Failure to follow this instruction may result in personal injury, economic loss or fire.

02. 

Do not use the unit in the place where flammable / explosive / corrosive gas, high 

humidity, direct sunlight, radiant heat, vibration, impact or salinity may be present.

Failure to follow this instruction may result in explosion or fire.

03.  Do not use the brake for safety.

Failure to follow this instruction may result in personal injury or product and ambient 

equipment damage.

04. 

Fix the unit on the metal plate.

Failure to follow this instruction may result in personal injury or product and ambient 

equipment damage.

05. 

Do not connect, repair, or inspect the unit while connected to a power source.

Failure to follow this instruction may result in fire.

06. 

Install the unit after considering counter plan against power failure.

Failure to follow this instruction may result in personal injury, economic loss or fire.

07. 

Check ‘Connections’ before wiring.

Failure to follow this instruction may result in fire.

08.  Do not disassemble or modify the unit.

Failure to follow this instruction may result in fire or electric shock.

09. 

Install the motor in the housing or ground it.

Failure to follow this instruction may result in personal injury, fire or electronic shock.

10. 

Make sure to install covers on motor rotating components.

Failure to follow this instruction may result in personal injury

11. 

Do not touch the unit during or after operation for a while.

Failure to follow this instruction may result in burn due to high temperature of the surface.

12. 

Upon occurrence of an error, disconnect the power source.

Failure to follow this instruction may result in personal injury, fire or electronic shock.

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01. 

Use the unit within the rated specifications.

Failure to follow this instruction may result in fire or product damage.

02. 

Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire.

03. 

The motor may overheat depending on the environment.

 

Install the unit at the well-ventilated environment and forced cooling with a cooling fan.

Failure to follow this instruction may result in product damage or degradation by heat.

04. 

Keep the product away from metal chip, dust, and wire residue which flow into the unit.

Failure to follow this instruction may result in fire or product damage.

Cautions during Use

• 

Follow instructions in ‘Cautions during Use’.

 

Otherwise, it may cause unexpected accidents.

• 

At low temperature, reducing the grease's consistency of ball-baring and etc. causes the 

friction torque increment.

 

Start the motor gradually since motor's torque is in normal state.

• 

The clack sound may occur when power is ON or OFF on brake.

• 

Release the brake before motor drive by supplying power on brake.

 

The product life cycle is shorten and the static friction torque reduces due to worn out brake 

pad.

• 

Be aware of backlash when positioning the motor in both CW/CCW directions.

 

Built-in gear type motor achieves low backlash due to high accuracy gear for positioning, but 

the problem may occur when positioning the motor in both CW/CCW directions.

 

In this case, the control is required to determine the position in either direction.

Содержание AK-G Series

Страница 1: ...conomic loss or fire 07 Check Connections before wiring Failure to follow this instruction may result in fire 08 Do not disassemble or modify the unit Failure to follow this instruction may result in fire or electric shock 09 Install the motor in the housing or ground it Failure to follow this instruction may result in personal injury fire or electronic shock 10 Make sure to install covers on moto...

Страница 2: ...environment condition rated in Specifications Altitude max 2 000 m Pollution degree 2 Installation category II OrderingInformation This is only for reference the actual product does not support all combinations For selecting the specified model follow the Autonics website A K 5 Max Allowable torque Number Max allowabletorque unit kgfcm Shaft type No mark Single shaft W Dual shaft Rated current S 0...

Страница 3: ... A200K 599 10 Max allowable torque 140 kgf cm 14 0 N m 200 kgf cm 20 0 N m Rotor inertia moment01 2 700 10 7 kg m2 Rated current M 1 4 A Phase G 2 8 A Phase Basic step angle 0 144 0 072 Full Half step 0 1 0 05 Full Half step 0 072 0 036 Full Half step Allowable speed range 0 to 360 rpm 0 to 250 rpm 0 to 180 rpm Backlash 15 0 25 Unit weight packaged 01 4 40 kg 4 88 kg 2 64 kg 2 74 kg 01 Listed in o...

Страница 4: ... torque MD5 ND14 24 VDC 1 4 A Phase 3 3 kpps MD5 HD14 24 VDC 1 4 A Phase 3 3 kpps MD5 HF14 220 VAC 1 4 A Phase 3 4 kpps A35K M566 W 5 Driver input frequency kHz 40 30 20 10 0 0 0 10 20 30 5 10 15 120 240 360 Rotation speed rpm Full Step Half Step Torque kgf cm Index Driver Power supply Setting current Max starting torque MD5 ND14 24 VDC 1 4 A Phase 2 3 kpps MD5 HD14 24 VDC 1 4 A Phase 2 3 kpps MD5...

Страница 5: ...8 A Phase 2 1 kpps A200K 599 W G7 2 Driver input frequency kHz 0 0 0 3 6 50 100 150 200 250 6 12 9 18 12 24 15 30 Rotationspeed rpm Full Step Half Step 250 200 150 100 50 Torque kgf cm Index Driver Power supply Setting current Max starting torque MD5 HF14 220 VAC 1 4 A Phase 1 8 kpps MD5 HF28 220 VAC 2 8 A Phase 2 1 kpps A200K 599 W G10 Driver input frequency kHz 0 0 0 10 20 30 5 10 15 60 120 180 ...

Отзывы: