3505 HUTCHINSON ROAD
CUMMING, GA 30040-5860
Quick Start Guide
Quick Start Guide
Quick Start Guide
SOLO Temperature Controller
SLB4848 Series
SOLO Basic
Specifications
Selection Guide
Part Number
Input Voltage
Output #1
Alarm #1* / Output #2**
Alarm #2*
SLB4848-R0
100 - 240 VAC
Relay - SPST
–
–
SLB4848-V0
100 - 240 VAC
Voltage Pulse
–
–
SLB4848-C0
100 - 240 VAC
Current
–
–
SLB4848-R2
100 - 240 VAC
Relay - SPST
Relay - SPST
Relay - SPST
SLB4848-V2
100 - 240 VAC
Voltage Pulse
Relay - SPST
Relay - SPST
SLB4848-C2
100 - 240 VAC
Current
Relay - SPST
Relay - SPST
*Alarm #1 and Alarm #2 have a shared common
** Alarm #1 can be configured to function as Alarm #1 or as Control Output #2
3
Controller and Panel Cutout Dimensions
5
This Quick Start Guide provides basic information on setting up the SOLO Basic temperature controller.
For advanced setup visit the AutomationDirect web site at www.AutomationDirect.com.
Box Contents and Unpacking Instructions
• Unpack the SOLO Basic temperature controller from its shipping carton. Included in the carton is the tem-
perature controller, mounting bracket plus hardware and this Quick Start Guide.
• Inspect all equipment for completeness. If anything is missing or damaged, immediately call the
AutomationDirect
returns department @ 1-800-633-0405.
• Inspect the part number to ensure the model received matches the output type required.
4
Mounting Bracket
and Hardware
SLB4848 Temperature
Controller
SLB4848
Quick Start Guide
Specifications
Input Power Requirements
100 to 240 VAC 50 / 60 Hz
Operation Voltage Range
85 to 264 VAC
Power Consumption
5 VA Max
Control Mode
PID, ON/OFF or Manual
Input Accuracy
TC temperature indication accuracy: ±(0.3% of span + 1 digit) at 25°C ambient after 20 minutes warm up.
Including NIST conformity, cold junction effect, A/D conversion errors and linearization conformity
RTD temperature indication accuracy: ±(0.2% of span +1 digit)
Vibration Resistance
10 to 55 Hz, 10 m/s
2
for 10 min, each in X, Y and Z directions
Shock Resistance
Max. 300 m/s
2
, 3 times in each 3 axes, 6 directions
Ambient Temperature Range
32°F to 122°F (0°C to 50°C)
Storage Temperature Range
-4°F to 149°F (-20°C to 65°C)
Altitude
2000m or less
Relative Humidity
35% to 80% (non-condensing)
IP Rating
IP66: Complete protection against dust and powerful water jets from all directions.
(**inside suitable enclosure)
Agency Approvals
UL, CUL, CE (UL file number E311366)
Pollution Degree
Degree 2 - Normally, only non-conductive pollution occurs.
Temporary conductivity caused by condensation is to be expected.
Input Types
• Thermocouple*
K, J, T, E, N, R, S, B, L, U, TXK (Sampling Rate: 100 ms / per scan)
• Platinum RTD
3-wire Pt100, JPt100 (Sampling Rate: 100 ms / per scan)
• Copper, Nickel RTDs
Cu50, Ni120 (Sampling Rate: 100 ms / per scan)
Control Output Options
• Relay (R)
SPST max. 5A @ 250 VAC resistive load
• Voltage Pulse (V)
DC 12V±15%, output current 40mA Max
• Current (C)
DC 4-20 mA output (sourcing) (Load resistance: Max 600
Ω
)
Alarm Output Option
(2) SPST relays with shared common, 3A @ 250VAC resistive load
*Note: Use only ungrounded thermocouples.
** No corrosive gases
Safety Information
WARNING! Electric shock danger
1. To prevent electric shock, do not touch the AC terminals while the power is supplied to the controller.
This controller is an open-type temperature controller. Make sure to evaluate any dangerous application in
which a serious human injury or serious property damage may occur.
1. Always use recommended solder-less terminals: Fork terminal with insulation (M3 screw, width is 5.8 mm, hole
diameter 3.2mm). Screw size: M3 x 5 (With square washer). Recommended tightening torque: 0.4 Nm. Applicable
wire: Solid/twisted wire 14AWG to 22AWG.
2. Protect the controller from dust or foreign objects to prevent controller malfunction.
3. Do not modify or disassemble the controller.
4. Do not connect anything to the “Not used” terminals.
5. Make sure all wires are connected correctly.
6. Do not install and/or use the controller in places subject to: (a) Dust or corrosive gases and liquid (b) High humidity
(c) Vibration and shock (d) EMI / RFI (e) high temperature.
7. Turn power off when wiring or changing a temperature sensor.
8. Be sure to use wires that match the thermocouple types when extending or connecting the thermocouple wires.
9. Use wires with correct resistance when extending or connecting a platinum resistance thermometer (RTD).
10. Keep the wire as short as possible when wiring a platinum resistance thermometer (RTD) to the controller and
route power wires as far as possible from load wires to prevent interference and induced noise.
11. This controller is an open-type unit and must be placed in an enclosure away from high temperature, humidity,
dripping water, corrosive materials, airborne dust and electric shock or vibration.
12. Make sure power cables and signals from instruments are all installed properly before energizing the controller,
otherwise serious damage may occur.
13. To prevent electric shock, do not touch the terminals in the controller or try to repair the controller when power
is applied.
14. Use a soft, dry cloth to clean the controller. Do not use acid or alkaline liquids for cleaning.
15. This instrument is not furnished with a power switch or fuse. Therefore, if a fuse or power switch is required,
install the protection close to the instrument. Recommended fuse rating: Rated voltage 250 V, Rated current 1
A. Fuse type: Time-lag fuse
16. Note: This controller does not provide overcurrent protection. Use of this product requires that suitable overcur-
rent protection device(s) must be added to ensure compliance with all relevant electrical standards and codes.
(Rated 250 V, 15 Amps max). A suitable disconnecting device should be provided near the controller in the
end-use installation.
1
WARNING:
To minimize the risk of potential safety problems, you should follow all applicable local and
national codes that regulate the installation and operation of your equipment. These codes vary from area to
area and it is your responsibility to determine which codes should be followed, and to verify that the equip-
ment, installation, and operation are in compliance with the latest revision of these codes.
Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes
and standards. We do not guarantee the products described in this publication are suitable for your particular
application, nor do we assume any responsibility for your product design, installation, or operation.
If you have any questions concerning the installation or operation of this equipment, or if you need additional
information, please call us at 1-800-633-0405 or 770-844-4200.
This publication is based on information that was available at the time it was printed. At
Automationdirect.
com®
we constantly strive to improve our products and services, so we reserve the right to make changes to
the products and/or publications at any time without notice and without obligation. This publication may also
discuss features that may not be available in certain revisions of the product.
Product Support
• For product support, specifications, and installation troubleshooting, a complete
User Manual can be downloaded from the On-line Documentation area of the
AutomationDirect
web site.
• For additional technical support and questions, call our Technical Support team
@ 1-800-633-0405 or 770-844-4200..
AutomationDirect’s SOLO Basic is a single loop temperature controller that can control heating or cooling
processes. Depending upon the particular model of controller, the available outputs include relay, voltage pulse
or current. On select models there are two alarm outputs available with nine selectable alarm types. SOLO Basic
controllers have a single control output that can be used for control of a heating or cooling application. Models
with alarm outputs can also be configured to use one of the alarm outputs as a second control output allowing
both heating and cooling control or two stage heating or two stage cooling control. There are three types of
control modes: PID, ON/OFF and Manual. SOLO Basic can accept various types of thermocouple and RTDs.
Other features include:
• Auto Tuning (AT) function with PID control
• 1/16 DIN panel size
• 2 line x 4 character 7-segment LCD display for Process Value (PV): Red color, and Set Point (SV): Green color
• Selectable display decimal point XXX.X or XXXX
• Selectable between °C and °F
• UL, CUL and CE agency approvals
General Description
2
Dimensions
inches [mm]