SC6 Series Signal Conditioners

This Quick Start Guide provides basic information for configuring the ProSense SC6 series signal condi-
tioners. For more specific information and additional instructions please visit www.AutomationDirect.
com and download the free instructions manuals for the SC6 series.

Description: 

Quick Start Guide

3505 HUTCHINSON ROAD 

CUMMING, GA 30040-5860

WARNING 

~

To avoid the risk of electric shock and fire, the safety instructions of this guide must be observed 
and the guidelines followed. The specifications must not be exceeded, and the device must only be 

applied as described in the following. Prior to the commissioning of the device, this installation guide must 
be examined carefully. Only qualified personnel (technicians) should install this device. If the equipment 
is used in a manner not specified by the manufacturer, the protection provided by the equipment may be 
impaired. Until the device is installed, do not connect hazardous voltages to the device.

In applications where hazardous voltage is connected to in /outputs of the device, sufficient spacing 
or isolation from wires, terminals and enclosure to surroundings (incl. neighboring devices), must be 

ensured to maintain protection against electric shock.

Potential electrostatic charging hazard. To avoid the risk of explosion due to electrostatic charging 
of the enclosure, do not handle the units unless the area is known to be safe, or appropriate safety 

measures are taken to avoid electrostatic discharge.

SAFETY INSTRUCTIONS
Receipt and unpacking

 

Unpack the device without damaging it. The packing should always follow the device until it has been 
permanently mounted. Check at the receipt of the device whether the type corresponds to the one ordered.

Environment

 

Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, as well as rain and heavy 
moisture. If necessary, heating in excess of the stated limits for ambient temperatures should be avoided 
by way of ventilation. All devices can be used for Measurement / Overvoltage Category II and Pollution 
Degree 2. The module is designed to operate safely at an altitude of 2000m or less.

Mounting

 

Mounting and connection of the device should comply with national legislation for mounting of electric 
materials, i.e. wire cross section, protective fuse, and location. Descriptions of input / output and supply 
connections are shown in this installation guide and on the side label. 
The device is provided with field wiring terminals and shall be supplied from a power supply having 
double or reinforced insulation. A power switch should be easily accessible and close to the device. The 
power switch shall be marked as the disconnecting unit for the device.
The 

SC6 Series

 must be mounted on a DIN rail that complies with EN 60715.

UL installation

 

Use 60/75°C copper conductors only.
Wire size ...................................... AWG 26-12
UL file number............................. E498965
The device is an Open Type Listed Process Control Equipment. To prevent injury resulting from access-
ability to live parts the equipment must be installed in an enclosure. 
The Division 2 or Zone 2 power supply unit must comply with NEC Class 2, as described by the National 
Electrical Code® (ANSI / NFPA 70).
cFMus installation in Division 2 or Zone 2
FM18US0045X .........................  Cl. I, Div. 2, Group A, B, C, D T4 
 

 

 

          or Cl. I, Zone 2, AEx nA IIC T4

FM18CA0023X .........................  Cl. I, Div. 2, Group A, B, C, D T4
 

 

 

           or Cl. I, Zone 2, Ex nA IIC T4

In class I, Division 2 or Zone 2 installations, the subject equipment shall be mounted within a tool secured 
enclosure which is capable of accepting one or more of Class I, Division 2 wiring methods specified in the 
National Electrical Code (ANSI/NFPA 70) or in Canada in the Canadian Electrical Code (C22.1).
The SC6 Series Isolators and Converters must be connected to limited output NEC Class 2 circuits, as 
outlined in the National Electrical Code® (ANSI / NFPA 70), only. If the devices are connected to a 
redundant power supply (two separate power supplies), both must meet this requirement. 
Where installed in outdoor or potentially wet locations the enclosure shall at a minimum meet the require-
ments of IP54. 

Warning:

 Substitution of components may impair suitability for zone 2 / division 2.

Warning:

  To prevent ignition of explosive atmospheres, disconnect power before servicing and do not 

separate connectors when energized and an explosive gas mixture is present.

Warning:

 Do not mount or remove devices from the power rail when an explosive gas mixture is present.

Cleaning

 

When disconnected, the device may be cleaned with a cloth moistened with distilled water.

Technical Specifications

Operating temperature .............................. - 25°C to +70°C (-13°F to 158°F)
Storage temperature ..................................  -40°C to +85°C (-40°F to 185°F)
Supply voltage........ ................................... 16.8...31.2 VDC
Supply voltage, SC6-6102 ......................... Loop -powered / 3.3...35 VDC
Supply voltage, SC6-7102 ......................... Loop -powered / 5.5...35 VDC
Supply voltage, SC6-1101, -1111............... 

 1.25 V + (0.015 x Voutput)

Supply voltage, SC6-4102, -4112, -1102, -1112..... Loop -powered /  

6.0...35 VDC

Max. required power:

SC6-5200, -6200........................................ 0.7 W
SC-1100, -1110, -3200, -7102, -6102........ 0.8 W
SC6-2200, -2220, -3220............................. 1.2 W
SC6-1101, -1111........................................ 30mW per channel
SC6-4102, -4112........................................ 50mW per channel
SC6-1102, -1112 ....................................... Vterminal x I per channel
¹Isolation voltage, test ................................. 2.5 kVAC
¹Isolation voltage, working ..........................  300VAC (reinforced) / 

250VAC (Zone 2, Div. 2)

Double isolation.......................................... Input/output 1/output 2/supply
Relative humidity........................................ < 95% RH (non-cond.)
Dimensions (HxWxD) ............................... 113 x 6.1 x 115 mm
Protection degree ........................................ IP20
Weight ....................................................... 70 g

Approvals

UL, Standard for Safety .............................. UL 61010 -1
Safe isolation .............................................. EN 61140
cFM us........................................................ Zone 2 / Div. 2

Observed authority requirements:

EMC ........................................................... 2014/30/EU
LVD ............................................................ 2014/35/EU
RoHS 2........................................................ 2011/65/EU

¹Does not apply to SC6-6102

Installation:

 

This installation guide for technical personnel covers the following products:

SC6-1100

SC6-1110

SC6-2200

SC6-3220

SC6-5200

SC6-7102

SC6-1101

SC6-1111

SC6-2220

SC6-4102

SC6-6102

SC6-PCU1

SC6-1102

SC6-1112

SC6-3200

SC6-4112

SC6-6200

Installation on DIN rail:

 

To avoid short circuit between the power rail connectors on the 
SC6 Series devices and the screws holding the 7.5 mm DIN rail, 
the head of the screws shall be no more than 3.5 mm high. SC6 
Series units must be supported by module stops (ADC Series 
KN-EB7).

 

< 3.5 mm

> 24 mm

 35 mm

Demounting from DIN rail:

 

First, remember to demount the connectors with hazardous volt-
ages. Detach the device from the DIN rail by lifting the bottom 
lock. 

Wire size AWG 26...12 / 0.13...2.5 mm2 stranded wire. Screw 
terminal torque 0.5 Nm.

 

Supply of the Power rail:

 

The power rail can be powered via the SC6-PCU1 Power Connector unit or alter-
natively a SC6 series unit with power rail connector power terminals. Max. current 
values are to be observed:
SC6 Series unit with power rail connector ......................0.4 A (protective fuse 0.4 A)
SC6-PCU1 unit..............................................................2.5 A (protective fuse 2.5 A)

Required external fuse:

Supply directly on device.................................................2.5 A
Supply of power rail using a standard device....................0.4 A
SC6-PCU1 Power connect unit.......................................2.5 A

Fuse Characteristics:

The 2.5 A fuse must break after not more than 120 seconds at 6.4 A.

Side Label 

}

}

}

}

DIP-switch 

settings

Approvals

Pin

connections

Terminal numbers

Part number

AutomationDirect

3505 Hutchinson Road

Cumming, GA 30040

800-633-0405

www.automationdirect.com

Copyright 2019, Automationdirect.com™ 

Incorporated All Rights Reserved